4. The insert is placed on two rails on top of the pallet.
In order to remove it from the rails and pallet, loosen
the screws and remove the brackets holding it in place.
Before lifting the insert of the pallet, fasten the screws
removed from the legs FIG 2.

Operational control

When the insert is in an upright position, and prior to
mounting the surround, check that all
functions are easy to use and appear satisfactory.
1. Adjust the legs. Make sure the insert is level
2. Loosen the transport safety. Make sure the
wires holding the door are in place.
3. Make sure the door can be opened and closed
properly.
Attention! The pulleys on each side of the door are
coated with special heatresistant grease. If a new
grease is needed, contact one of our dealers to
make sure the right type of grease is used.
A
Air vent control
Air vent control
Left position = closed
Right position = open
Self closing door
To make the door self closing, do as follows;
1. Use a flat screwdriver to move the three clamps
holding the weights in place outwards FIG 4(A)
2. Remove the weight fittet positioned slightly higher
FIG 4(B)
3. Carefully push the clamps back in place.
Cleaning the glass FIG 5-5B
If it becomes necessary to clean the glass depends on
side, pull out the two small handles above and the door
to keep it in place and open the door. After cleaning the
glass, first lock the handle on the left side of the door
before pushing the two small handles back in place.
Caution!! Be careful when opening the door
sideways. Some surronds have marble/waxed
concrete parts and grates quite close to the door
and both the door and surrounding parts may
sustain damage if carelessly operated.
Radiation shields, rear and around smoke collar.
Assembling of the heat shields is shown on FIG 6-6b.
To utilize the rear or side connection, remove the cut in
B
Igition
Ignition position
Fully to the right
the radiation shield. To keep the smoke collar radiation
shield in place, push the upper and lower cuts in
towards the smokepipe.
Thermotte, assembly FIG 9-12
Open the door (follow the instructions on how to clean
the glass). Place the Thermotte as show in the
illustrations.
Powerstone assembly
Powerstone is an accessory. For assebling see a
separate instruction - see FIG 14 - FIG 15.
Flue collar and connection
Attention! Our inserts are prepared for
connecting the smoke pipe on the outside of the
flue collar Ø150 - see FIG 4B.
*Alternative versions of the flue collar exsist due to
National requirements. For the connection to the
chimney, follow the recommendations from the chimney
manufacturer
Painting the surround
It is recommended to use the insert a few times in order
to let the varnish harden before any eventual masking
and painting. Only use water based breathing paint and
a designated masking tape. Carefully remove the tape
in order not to damage the varnish.

5. Lighting the fire for the first time

When the insert is installed and all instructions have
been observed, a fire can be lit.
Take care when inserting logs into the burn chamber,
in order not to damage the Thermotte plates. Please
note that there might be some humidity in the insulation
plates which can result in a slower burn rate the first few
times the insert is used. This will be resolved once the
humidity has evaporated. It is advisable to ventilate
the room well when using for the first time as the
varnish on the product may release some smoke or
smell. Both the smoke and smell will disappear and are
not hazardous.
! Close the insert door during usage
See separate usage and maintenance manual
Warning!
In order to avoid injuries, please be aware that the
surfaface may become hot during operation.be hot and
that extra care need to be taken to avoid skin burn.