852-303 8/2-Port 100Base-TX/1000Base-SX/LX
Tabelle 161: MODBUS-Register
Register-
adresse
0x087b
0x087c
0x087d
0x089e
0x089f
0x08a0
0x08a1
0x08a2
0x08a3
0x08a4
0x08a5
0x08a6
0x08c7
0x08c8
0x08c9
0x08ca
0x08cb
0x08cc
0x08cd
0x08ce
0x08cf
0x08f0
0x08f1
0x08f2
0x08f3
0x08f4
0x08f5
MSTP Information
0x0900
0x0901
Handbuch
Version 1.3.0
Datentyp Dar-
Beschreibung
stellung
1 word
Hex
Ring ID for ERPSn (n=4)
1 word
Hex
State for ring of ERPS
33 words
Hex
Name of Ring
1 word
Hex
Version & Ring Type
1 word
Hex
Instance of Ring
1 word
Hex
Control VLAN of Ring
1 word
Hex
Right Port of Ring
1 word
Hex
Left Port of Ring
1 word
Hex
Ring port state
1 word
Hex
Ring ID for ERPSn (n=5)
1 word
Hex
State for ring of ERPS
33 words
Hex
Name of Ring
1 word
Hex
Version & Ring Type
1 word
Hex
Instance of Ring
1 word
Hex
Control VLAN of Ring
1 word
Hex
Right Port of Ring
1 word
Hex
Left Port of Ring
1 word
Hex
Ring port state
1 word
Hex
Ring ID for ERPSn (n=6)
1 word
Hex
State for ring of ERPS
33 words
Hex
Name of Ring
1 word
Hex
Version & Ring Type
1 word
Hex
Instance of Ring
1 word
Hex
Control VLAN of Ring
1 word
Hex
Right Port of Ring
1 word
Hex
Left Port of Ring
1 word
Hex
Ring port state
1 word
Hex
Instance ID (Fixed 0x00, 0)
High byte –Instance ID.
Low byte –Used State.
0x01: used
0x00: non used
3 word
Hex
Root bridge MAC
Ex: MAC=00:01:02:03:04:05
Word 0, high byte=0x00.
Word 0, low byte=0x01.
Word 1, high byte=0x02.
Word 1, low byte=0x03.
Word 2, high byte=0x04.
Word 2, low byte=0x05.
Anhang