2 m
1
m
CHIMNEY CAPS - DISTANCES AND POSITIONING
Inclination of the
roof
α α α α
15°
30°
45°
60°

6. CONNECTION TO THE CHIMNEY

For safety reasons the door of the hearth can be open only during the fuel loading. The hearth must remain closed
during the operation and the periods of non-use.
The chimney stove is equipped with an upper and rear smokes exhaust for (see on pages 50 for the assembly of
particular components in order to change the smoke exhaust).
The junction pipe for the connection to the chimney must be the shortest possible and the junction points of the single
pipes must be hermetic. The connection to the chimney must be performed with stable and strong pipes (we
recommend a thickness of 2 mm). The pipe for smokes exhaust must be fixed hermetically to the chimney. The
diameter inside the connection pipe must correspond to the external diameter of the smokes exhaust small trunk of
the stove. This is ensured by pipes according to DIN 1298.
ATTENTION: Eventual flammable pieces in the area of 20 cm round the connection pipes must be changed with
fireproof and not sensitive to heat materials.
20
GIULIETTA – ISETTA-07 – ISOTTA-07 – ISOTTA FORNO – VIOLA – VIOLETTA
10 m
(1) The chimney cap must not show hindrances within 10 m from
walls, pitches and trees. Otherwise raise it of at least 1 m over
the hindrance.
The chimney cap must exceed the ridge of the roof of at least 1
m.
>A
H min.
(1)Ridge axis
α
Distance between the roof
ridge and the stack
A (m)
< 1.85 m
> 1.85 m
< 1.50 m
> 1.50 m
< 1.30 m
> 1.30 m
< 1.20 m
> 1.20 m
> _ A
0,5 m
(2)Roof
Minimum height of the stack (measured from
0.50 m above the roof ridge
1.00 m from the roof
0.50 m above the roof ridge
1.30 m from the roof
0.50 m above the roof ridge
2.00 m from the roof
0.50 m above the roof ridge
2.60 m from the roof
UNI 10683/98
the outlet)
H (m)