12. LiFe Batteries – Charging / Balance-Charging/

Fast-Charging / Storage-Automatic / Discharging

The necessary basic settings for Lithium Ferrit batteries have to be
entered in the USER SET program of the CS-Space X4 Charger. Select with
the Batt.Type key "USER SET PROGRAM" and confirm it with the Enter-
key. Now change the displayed setting of LiPo V.Type 3.7V by pressing
the START/ENTER-key and the -DEC/+INC-keys to LiFe V.Type 3.3V. Save
the change by pressing the START/ENTER-key.
Select with the Batt.Type-key „PROGRAM SELECT LiFe Batt" and con-
firm it with the Enter-key. Now select the program you need with the
-DEC/+INC-keys.
Charging (LiFe CHARGE), use this only if you have no balancer cable.
Balance-Charging (LiFe BALANCE), is recommended, connection to the
balancer is necessary!
Fast Charging (LiFe FAST CHG), shortened charging time!
Storage-Automatic (LiFe STORAGE), important for the life time!
Discharging (LiFe DISCHARGE), only used in special cases, pay attention
to the cell end voltage of 2.0V per cell!
You confirm the program with the enter-key and by pressing the enter-
key again, the charge current is flashing. Now set the charge current
with the -DEC/+INC-keys according to the manufacturer's indication.
The values are saved with another pressing of the start/enter-key.
Now you have to set the flashing information displayed on the right side
according to the voltage of the LiFe battery and confirm it with the
enter-key.
Charging of LiFe-batteries with the balancer program: This function
allows the balancing of the voltage of Lithium batteries when charging.
You have to connect the battery with additional balancer cable with
the charger. Charging t with this program is different to the "normal"
modes, cause the voltage of each cell of the battery is checked and will
be adjusted by a different charging current.
When discharging, you have to enter the cell end voltage according
to the manufacturer's indication. Normally it is 2.0 V per cell and you
should not underrun this voltage. To give you an idea the additional information
of the number of cells can be helpful like 4.0V(2S) for 2 cells or 6.0V(3S) for 3 cells. Please refer
to the safety notes.
If you now press the start/enter-key for more than 3 seconds, the selected process starts in a
safe mode and your settings are checked. The number of the cells
detected by the charger are marked with "R" and with "S" the
number of cells you have entered. If both values are the same, the
display shows "ENTER". You can now start the charging process by
pressing the enter-key.
If the values are not the same, the charger beeps and you have to press the Batt-Type/Stop-key.
After that you can enter the correct number of cells respectively the voltage.
To interrupt or to break off the charging process press the Batt.Type/Stop-key.
The completion of the charging process is shown by a flashing "Full" in the display.