7. Preparing the Charger

Connect the CS-Space X4 Charger with a power supply of 11 to 15 V DC or a 12-V car battery.
With the Batt.-Type key you select the battery type or you stop a process.
With the Enter-key you start a process or you save values.
With the -DEC/+INC-keys you change values in the flashing mode or you can display the configu-
ration when charging.
Only use suitable charge- and balancer cables to avoid a malfunction. Make sure, that the polari-
ty of the different plugs fit your battery, before you use the charger.

8. NiCd Cells

Charging / Discharging / Cycling

Select with the Batt.Type-key „PROGRAM SELECT NiCd Batt" and confirm it with the Enter-key.
Now select the program you need with the -DEC/+INC-keys:
Charge (NiCd CHARGE)
Discharge (NiCd DISCHARGE), pay attention to the cell end voltage of
0,85V per cell!
Cycling (NiCd CYCLE), for charnging and discharging the settings of
the first two programs are used.
You confirm the program with the enter-key and by pressing the enter-key again,
the charge current is flashing. Now set the charge current with the
-DEC/+INC-keys-keys according to the manufacturer's indication.
Pressing both status-keys simultanously in the charging program,
the mode will be changed from „manual" to „automatic". Using the
automatic-mode you can set an maximum charging current, which
will not be exceeded. The Ultra Space Charger sets the current ac-
cording to the measured data of the battery. In the „manual" mode
the the battery is charged with the current as set.
The values are saved with another pressing of the start/enter-key.
If you now press the start/enter-key for more than 3 seconds, the
selected process starts with the battery check and changes after that
to the survey.
Changing the charging current while charging: Press the enter-key
and change the current with the -DEC/+INC-keys-keys without
interrupting the charging process. You confirm the change with
the enter-key.
To interrupt or to break off the charging process press the Batt.
Type/Stop-key.
The completion of the charging process is shown by a flashing
"Full" in the display.
Attention: Please check that the basic setup of the charger has
already been done and that the battery type correspond to the
selected charging program!