Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Notices; Fault Indications And Rectification Of Faults - Caso WineMaster 126 (665) Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für WineMaster 126 (665):
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10

16.1 Safety notices

Attention
► Only qualified electricians, who have been trained by the manufacturer, may carry out any
repairs on electrical equipment.
► Improperly performed repairs can cause considerable dangers for the user and damages
to the device.

16.2 Fault indications and rectification of faults

The following table assists in localizing and rectifying minor faults.
Fault
Wine refrigerator do not
operate.
Your device is not cold
enough or it does not reach
the adjusted temperature:
The light does not work.
Vibrations.
The wine refrigerator seems
to make to much noise
The door will not close
properly.
LED could not display.
LED display error - Lo
Bottoms are not functional.
Compressor will not start
Compressor re-start
caso Wine Master
Not plugged in using different voltage. The circuit breaker
tripped or a blown fuse.
Check the temperature control setting.
External environment may require a higher setting.
The door is open too often. The door is not closed
completely. The door seal does not seal properly.
The wine refrigerator does not have the correct
clearance.
Defrost the device.
Check the service center.
Check to assure that the wine refrigerator is level.
The wine refrigerator is not level.
Check the fan.
The wine refrigerator is not level.
The door is reversed and not properly installed.
The seal is weak. The shaves out of position.
Main control board does not work.
PCB Problem. There is some problem with the plug.
Weak quality of display.
Temperature point is out off.
Contact the service center.
Temperature controller panel is damaged.
Room temperature is lower than desired temperature.
Compressor will stop working when cooling system in the
cabinet reaches
presetting temperature, and re-start
working until the desired temperature is achieved.
Allow a minimum 5 minute interval before re-starting.
Possible Cause
35

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Winemaster 180 (670)

Inhaltsverzeichnis