The activated carbon filter are not supplied. You can order the carbon filter from your dealer or in our online accessories shop, www.bomann.de. To
order, use the reference number found under "Technical Data".
Assembly
WARNING:
• When assembling or inserting the extraction filter as well as the carbon filter, the appliance must not be connected to the mains.
• Failure to use the mounting fixtures may lead to a risk of electric shock.
CAUTION:
• Before mounting, check that the wall has sufficient load capacity to bear the extractor hood.
• When drilling the holes in the wall always make sure that no existing electrical cables or other objects are damaged.
• Make sure that the vents are clear of obstacles and are not covered.
NOTE: Recommendations for preparation work
• When installing, ask another person to assist.
• Wear protective gloves to prevent injuries from any sharp edges.
1
4
• Determine the position of the extractor hood centrally above the hob in conformance with the specified safety distances.
• Mark the necessary holes for the wall mounting and check them with a spirit level.
• Drill Ø 8 mm mounting holes into the wall for the respective brackets (1+2+3). Insert the dowel pins (5) and fasten the brackets with the screws (6)
(Fig. A+B).
• Attach the suspension rail (1) for the hood as well as the mounting rail with bracket (2) to the top edge parallel to the rail (1) (Fig. B). Determine the
extension length of the duct cover in advance!
• Insert the non-return valves (4) onto the extractor duct from above by gently bending them.
For extraction mode:
• A flexible extraction hose (not supplied) with an inner diameter of Ø 150 mm must be attached and connected to the outside by the extraction
outlet.
• Hook the extractor hood into the suspension rail (1) (Fig. C). Check that it is secure and horizontally level.
• Remove the protective plastic from the telescopic duct.
• Fasten the outer (bottom) duct to the mounting rail without the bracket (3). The rail is fastened to the holes provided from the inside of the duct.
Screw in two plate screws (7) from the back (Fig. D).
• Place the outer (bottom) duct with the rail (3) onto the extractor hood (Fig. E). Fasten the rail (3) to the wall parallel to the other rails (1+2).
• Slide the inner (top) duct along the slide fixture into the outer (bottom) duct. Make sure that the inner duct is aligned with the vents at the top.
Determine the extension length of the duct cover by pulling up the inner duct or sliding back into the outer duct.
• For extraction mode, correctly position the flexible extraction hose (not supplied).
• Pull the inner duct cover up and fasten the duct unit on the side to the previously mounted rail (2) by screwing in the plate screws (7) (Fig. F).