CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the unit, in particular the output nozzle. Please use a soft lint-free and
moistened cloth for the outside of the unit. Never use alcohol or solvents!
Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container and
the fog machine liquid tank immediately after filling.

Cleaning the Heating Element

The heating element should regularly be cleaned every 40 operational hours in order to avoid clogging. Use
fog machine cleaner available at your dealer.
All fog machines are prone to clogging due to the thick consistency of fog liquid and the high temperature at
which it vaporizes. However, a properly maintained fog machine should provide years of reliable use.
Procedure:
Fill cleaner into empty tank. Run the machine several times in a well-ventilated room only. The number of
repetitions depends on the pollution level of the vaporizing elements. After use, clean all remaining cleaner
and rinse the tank thoroughly.
The EUROLITE fog fluids we recommend are non-hazardous to the environment and can be disposed of via
the sewage system.
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.

Replacing the Fuse

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating. Before
replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
If defective, please dispose of the unusable device in accordance with the current legal regulations. Should
you have further questions, please contact your dealer.

Storage

It is recommended to operate the machine at least once a month with a warm-up period and a few minutes
of fog emission. Prior to storage, run cleaning fluid through the system as described in the cleaning regimen
above. This will help avoid any particles condensing inside the pump or heater.
www.eurolite.de
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
30

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis