• Unscrew the cable inputs on the bottom of the
device and pass the mains connection cable
(max. Ø 10 mm) through the left input to the
connection clamp.
• Insert the cable ends, with approximately 6
mm of insulation removed into the "KL 1"
clamps (5) and screw them securely into place.
• If the relay switching contact is to be used for the switching of the circulation pump or for controlling
the heating system (more information in the chapter "Using the internal relay"), then the load cable
must be connected to the "KL 2" clamp (6) in the same manner as the mains cable.
You must observe and adhere to the maximum capacity and fusing in the chapter "Using the internal
relay".
The following sketch shows the wiring of the mains connection and load connection:
5
6
29