6. Operation

6.1 Safety instructions for operation

Warning
Danger through improper operation
Operation only by sufficiently qualified and authorised
personnel.
Only operate tap when it is in perfect working condition.
Always keep the operating manual in good, readable condition
and completely accessible at the site of usage of the tap
Hot pipelines or tap surfaces through operating with hot media
Danger of burning at contact.
Avoid contact.
Wear personal safety equipment.
When the valve of the refill unit closes, you may hear a "closure snap"
in the line system.

6.3 Control elements and LED displays

NK300T-1/2A
Error (Fehlermeldung)
Pressure Setting (Solldruck)
Time (Maximale Füllzeit)
Hysteresis (Hysterese)
Cycle (Überwachungszyklus)
Water Consumption (Wasserverbrauch)
Overflow (Bereichsüberschreitung)
ENTER
PN
: 10 bar
P
: P
0,1...6,0 bar
IN
min max
P
: P
1,5...4,0 bar
OUT
min max
T
: T
1...30 min.
fill
min max
Supply voltage 12V DC
---o-o-o

6.4 Overview, operating modes

Mode
Display
AUTOMATIC

SYSTEM FILLING

CONFIGURATION

MALFUNCTION
Honeywell GmbH
The refill unit is controlled through three buttons on the top side. Display of the operating
statuses is shown through LEDs and seven-segment display.
LED green
Auto / Liter
LED yellow
Fill / Liter x 10
2
LED red
3
Config / Liter x 10
Button, HAND/ AUTOMA-
TIC/ ENTER
Button, DOWN
Button, UP
Description
System pressure is measured.
See chapter 6.4.1
The system is being filled
See chapter 6.4.2
Entering the parameters: pressure setting, filling time, hysteresis, cycle time, quantity limit
Display of remaining capacity, counter status, water use
See chapter 6.4.3
Display of error code
See chapter 6.4.4
GB

6.2 Definition of terms

Hysteresis
Band around pressure setting in bar.
The upper limit is calculated from the
pressure setting+(hysteresis/2)
pre-set in the factory to 0.2 bar
Pressure setting
The system's pressure setting is pre-set at the
factory at 2 bar
Time
Time in which the system has to reach the top
pressure value during backfeed,
pre-set at the factory at 15 min
Cycle
Number of measurements per hour,
pre-set at the factory at 2
Water
Total water consumption of the system. Serves
to detect system leakages
Overflow
Top limit of measurable water consumption
Switch-off quantity
Automatic switch-off after a set quantity of water
flows through
This function is necessary when using softening
cartridges
Remaining capacity
Display of the remaining capacity when using
softening cartridges
Description
Display of automatic mode
Display of filling mode / system filling
Display of configuration mode
Changeover between automatic and configuration mode
Adoption of set values
Decrease set values
Raise set values
19