2.4 General information

2.4.1 Conformity with the following norms

EMC directive 2004/108/EG (only with correctly connected cable and plug
and sockets)
Low voltage directive 2006/95/EC

2.4.2 Warranty and liability

As a matter of principle, the general sales and delivery terms of the Honey-
well Company apply. Warranty and liability claims for injury to persons and
damage to property are ruled out if they arise from one or more of the follo-
wing causes.
• Non-intended use of the tap
• Improper assembly, start-up, operation and maintenance of the tap
• Non-compliance with the instructions in the operating manual as regards
transport, storage, assembly, start-up, operation, maintenance and
servicing of the tap
• Non-authorised constructional modifications on the tap
• Negligent monitoring of components subject to stress
• Improperly performed repairs
• Catastrophes through effect of a foreign object or force majeure

3. Technical data

Installation position Installation in horizontal pipelines with control unit placed upwards
Medium
Drinking water
Medium tempera-
Inlet side: 5 °C to 30 °C, outlet side: 5 °C to 65 °C
ture
Pressure range
Input side
0.1 to 6 bar
Output side
1.0 to 4 bar
Totalizer range
0.1 litres up to 99m³ (display double-digit + unit)
Flow rate
max. approx. 800l/h
Dimensions
225 x 115 x 143 mm (L x W x H)
Weight
approx. 1.8 kg
Housing material
dezincification-resistant brass
Sealing material
EPDM
Connections
2x external thread 1/2"
(1 adapter included for 3/4" internal thread)
Voltage
12V DC via wide-area power pack included in delivery
Power consumption < 3W non-operation reception
max. 12W (valve open)
Alarm contact
Potential-free closer, 24V / 2A max.
Service interface
Mini-USB port, form "B"
Protection class
IP 54 according to EN 60529
(ensured only with correctly connected cable, correct installation of the insulation shell elements and horizontal installation position)
Connections
Hollow plug 5.5mm

3.1 Authorised environmental conditions

Ambient temperature 5 °C to 50 °C (power pack and cable: 0 °C to 40 °C)
Relative air humidity max. 80% r.h.
Honeywell GmbH
GB

2.4.3 Storage and perfect condition

This operating manual is a part of the tap and must be accessible in its
complete form at all times. Any instruction or page that is missing has to be
replaced immediately.

2.4.4 Illustrations

The illustrations used are examples of a potential version of the tap and
might differ in individual cases from the actual tap version.

2.4.5 Symbols

1. Start of a task description
2. Next work step
- Result of an action
• List of several options
Reference to other documents
Pictogram
Danger classification
Danger source
Consequence of non-compliance
Avoidance
16
MU1H-1551GE23 R0911

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis