Herunterladen Inhalt Inhalt Diese Seite drucken

Continuity Test, General - VOLTCRAFT LSG-3 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Continuity test, general

The net toner can be used as an optical continuity tester.
Make sure before connection that the cables are not
alive (danger to life).
• Turn the switch-over for test mode (22) to the central position
"OFF".
• Connect the two test terminals (24) using the cable to be tested.
• Turn the switch-over (22) to the left to the position "CONT/Talk".
The pushbutton (20) may not be pressed.
• The green LED display (21, line2/continuity) displays the continu-
ity status:
brightly lit = little cable resistance
medium-lit = high cable resistance
not lit = interrupted current circuit
• Turn the switch-over (22) after the end of the test to the central
position "OFF" again.
If the ends of the cables to be tested lie too far apart, use
a second reference lead for a return path. Wire these two
cables together at the end furthest away.
30

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis