TECHNICAL SPECIFICATION

(tested under the conditions of ambient temperature 15°C and tap water temperature 10°C)
Model
Ice Making Capacity – 24
hours
VDB-26
26Kgs
VDB-50
50Kgs
The specifications are subject to be changed without notice. Please check the nameplate for sure.

TROUBLE AND SHOOTING

(for reference of users and technicians)
Disconnect Ice Maker from power before carrying out any of these checks.
TROUBLE
1.The voltage is out of the
limitation.
The ice marker does
2.The ambient temperature is
not work
lower than 10º C.
1.Water shortage from the water
supply system.
Water shortage
2. Water valve damaged.
indicator lights on.
3.Tap water pressure too low.
1.Water shortage.
Compressor doesn't
2.Ice full.
work
1.Refrigerant leakage.
2.The refrigerating system is
Compressor works,
blocked.
but no ice is made.
1. Water temperature or
It is difficult for ice
dropping or ice
2. The solenoid valve is
cannot be dropped.
Trouble indicator
The water box does not tilt.
lights on.
7
Climate
N
N
CAUSE
ambient temperature is too
low.
damaged.
Electrical
Power Input
Class
(W)
I
220
I
280
REMEDY
1.Stop the ice maker and restart it until the
voltage is normal.
2.Try again when the ambient temperature
higher than 10ºC
1.Check the water supply.
If it is OK, restart the maker.
2.Check the water valve.
3.Be sure the tap water pressure is higher
2
than 1 kg/cm
1. Check the water supply system (water
valve and water supply tube).
2. Take out some ice.
1.Recharge the refrigerant and check the
leakage again.
2.Charging N2to check whether
The system is blocked and replace the
dryer-filter
3.Replace the solenoid valve
4.Check whether the fan is running.
1. Check whether the ambient
temperature is too low (Lower than 10 ºC)
or water temperature is too low(lower
than 7 ºC)
2. Replace the solenoid valve.
Unplug the power, check the tiling motor
and relative system. 3~5 minutes later
restart the machine.
Dimension
L×D×H(mm)
420×528×655
496×610×792

Werbung