Herunterladen Inhalt Inhalt Diese Seite drucken

Absolute Filter Assembly Or Replacement; Tightness Inspection; Disposing Of The Vacuum Cleaner - Nilfisk-ALTO ATTIX 125-01 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39
ATTIX 115-01 / ATTIX 125-01

Absolute filter assembly or replacement

Do not use the absolute filter again after having
removed it from the vacuum cleaner.
1.
Vacuuming unit
2.
Closing band
3.
Filter shaker stop
4.
Filter shaker knob
5.
Washer
6.
Ferrule
7.
Absolute filter
8.
Seal
9.
Disc
10. Nut
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
Assembly
1.
Release the stop (3) and unscrew the filter shaker knob
(4), release the closing band (2) and remove the head
(1).
2.
Unscrew the nut from the ferrule under the head (1),
insert the washer (5), screw the ferrule (6), insert the
filter (7), the gasket (8) and the disc (9), screw the nut
(10), fit the head back in position and fix with the closing
band (2), screw the knob (4) and lock it with the stop (3).
Replacement
1.
Proceed as indicated in step 1 of the assembling
procedure.
2.
Unscrew the nut (10), remove the disc (9) and the gasket
(8).
3.
Replace the filter (7) and proceed in the reverse order to
reassemble the head.
GB
To dispose of the filter put it in a sealed plastic bag, close it
hermetically and dispose of it in accordance with the laws in
force.
C365
WARNING!
Figure 9
WARNING!

Tightness inspection

Hoses check
Make sure the connecting hoses (Fig. 10) are in a good
condition and correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
When sticky materials are treated, check for possible clogging
along the hose, in the inlet and on the baffle plate inside the
filtering chamber.
Scrape inlet (2, Fig. 10) from the outside and remove the
deposited waste as indicated in the figure.
Filtering chamber tightness check
If gasket (1, Fig. 11) between container (4) and filter chamber
(3) fails to guarantee a good seal:
Loosen the four screws (2) that lock the filtering chamber
(3) against the vacuum cleaner structure.
Allow the filtering chamber (3) to lower down and tighten
the screws (2) once it has reached the tightness position.
If an optimal seal cannot be obtained and the gasket is torn or
cracked, etc. it must be replaced.

Disposing of the vacuum cleaner

Dispose of the vacuum cleaner in compliance with the laws in
force.
Proper disposal (electric and electronic waste).
(Applicable in the European Union and in countries
providing a separate collection system)
The above symbol (Fig. 12), which is present on the product
or in its documentation, indicates that the product cannot be
disposed of together with other domestic waste at the end of
its life cycle.
To prevent damage to the environment or health caused by
improper waste disposal, please separate this product from
other waste and recycle it responsibly in order to support the
sustainable reutilisation of material resources.
This product can not be disposed of together with other
commercial waste.
10
Figure 12
11/2010

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Attix 115-01

Inhaltsverzeichnis