The following laser lines can be switched on together or separately by pressing the below buttons:
Line „H"
Line „V1"
Line „V2"
All lines
Receiving mode
Press button „P" on the instrument to change to the receiving mode (the LED will be illuminated). The
receiver FR 55 / FR 55-M can now detect the signal of the laser (the visibility of the laser lines is weaker
in this mode). The working range can be extended to 60 m by use of the receiver.
G

MANUAL FUNCTION

The MANUAL function is only available in the OFF mode (as otherwise compensator alarm would start).
Press the MANUAL key and select the desired laser lines. Now Geo5X-L360 HP can be used in slope
position.
ACCURACY CHECK
Set up instrument in the middle of two walls which are about 5 m apart. Mark visible laser cross on one
wall. Turn unit to opposite wall and mark laser cross.
Repeat measurements with distance of about 0,6 m to one wall and about 4,4 m to second wall. Devi-
ation between two measurements taken from the centre and two measurements taken at 0,6 m and
4,4 m must not exceed 3 mm.
Testing accuracy of horizontal line (end to end)
Set up instrument about 5 m from a wall. Mark laser cross on wall. Turn instrument until the laser cross
has moved about 2,5 m to the left side and check if horizontal line is within ± 2 mm of laser cross mar-
ked on wall. Repeat measurement by turning instrument to the right side
Testing accuracy of vertical line (end to end)
Set up instrument about 5 m from a wall. Fix a plumb line of 2,5 m length to the wall, using a plumb
bob. Bring laser line into coincidence with the plumb line. Deviation between laser line and plummet
cord from top to bottom must not exceed ± 1,5 mm.