Herunterladen Diese Seite drucken

Power Cut-Off Function - STG-BEIKIRCH M2/300-500N/EV1/RWA Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für M2/300-500N/EV1/RWA:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SHE linear drive M2/...-500N/EV1/RWA
Fields of application
Frame brackets K28/B and K29/B with 2 special clamping screws for the side clamping guides.
Can be used up to 500 mm stroke over the whole length of the drive, from 500 mm stroke in the first third of the drive.
Frame bracket K27/B with slide bracket for the bottom clamping guide. Can be used over the whole length of the drive.
The slide bracket has to be fixed at the linear drive with a starting power of 7.5 Newton meter (+/- 0.5 Nm).
top
Frame bracket K31 with 2 grub screws with points for the side assembling.

Power cut-off function

This function is operated using the electronic power cut-off fitted and does not require a limit switch.
Internal mechanical limit stops provide exact limits without disruptive stroke after-running. When these limit stops are
reached or block a drive in the UP-direction, the electronic power cut-off switches all drives off thanks to the increased
engine power. As the motor power is proportional to the shear and tensile forces this switch off takes place at exactly
defined forces.
Caution: Destruction of the motor. Never operate the linear drive without power cut-off.
Operate the load switch in general with 24 V protective extra low voltage.