Safety precautions
2-3. Checking for presence of
refrigerant
• The area shall be checked with an
appropriate refrigerant detector
prior to and during work, to
ensure the technician is aware of
potentially flammable atmospheres.
• Ensure that the leak detection
equipment being used is suitable
for use with flammable refrigerants,
i.e. non sparking, adequately
sealed or intrinsically safe.
• In case of leakage/spillage
happened, immediately ventilate
area and stay upwind and away
from spill/release.
• In case of leakage/spillage
happened, do notify persons down
wind of the leaking/spill, isolate
immediate hazard area and keep
unauthorized personnel out.
2-4. Presence of fire extinguisher
• If any hot work is to be conducted
on the refrigeration equipment or
any associated parts, appropriate
fire extinguishing equipment shall
be available at hand.
• Have a dry powder or CO
extinguisher adjacent to the
charging area.
10
ACXF55-17710_book1.indb 10
ACXF55-17710_book1.indb 10
2-5. No ignition sources
• No person carrying out work in
• All possible ignition sources,
• Prior to work taking place, the
• "No Smoking" signs shall be
2-6. Ventilated area
fire
• Ensure that the area is in the open
2
• A degree of ventilation shall
• The ventilation should safely
relation to a refrigeration system
which involves exposing any pipe
work that contains or has contained
flammable refrigerant shall use
any sources of ignition in such a
manner that it may lead to the risk
of fire or explosion. He/She must
not be smoking when carrying out
such work.
including cigarette smoking, should
be kept sufficiently far away from
the site of installation, repairing,
removing and disposal, during
which flammable refrigerant
can possibly be released to the
surrounding space.
area around the equipment is to
be surveyed to make sure that
there are no flammable hazards or
ignition risks.
displayed.
or that it is adequately ventilated
before breaking into the system or
conducting any hot work.
continue during the period that the
work is carried out.
disperse any released refrigerant
and preferably expel it externally
into the atmosphere.