6
Additional installation suggestions which, from experience, reduce the effect of
electromagnetic interference:
Make line connections as short as possible.
Only use the prepared cables with a sufficient diameter.
Keep the instrument well away from the electrical supply lines of power equipment, as
well as from any electrical or electronic equipment causing interference.
6. Pin Connections
M12x1 plug
E
Pin
Signal
1
CAN_SHLD
2
CAN_V+
3
CAN_GND
4
CAN_H
5
CAN_L
Pin assignment according to CIA-DR-303 Part 1: Cabling and connector pin assignment
WARNING !
7. Protocol data for SAE J1939
Data Link Layer
Network Layer
Network Management
Default Settings:
CAN Data Source Address 1
Baud Rate
Transmission rate [ms]
Data length [Bytes]
Priority
PDU format
PDU specific
Additional information can be obtained from the"Protocol Description of SAE J1939 HIT 1500"
Edition: 2017-06-30
Description
CAN shield
CAN external positive supply
Ground / 0V / V-
CAN_H bus line (dominant high)
CAN_L bus line (dominant low)
Wiring, opening and closing of electrical connections must be carried out
in de-energized condition only!
Short-circuits, voltage spikes etc. can cause malfunctions and
uncontrolled conditions of the installation and constitute a serious risk of
personnel injury or damage to property.
SAE SAE J1939-21
SAE SAE J1939-31
SAE SAE J1939-81
250 kBit
100
8
6
255
0, 1, 2, 3
HYDAC ELECTRONIC GMBH
Female connector M12x1
HIT 1500 SAE J1939
Part No.: 669997