Herunterladen Diese Seite drucken

Siemens 7LF4 4015 Handbuch Seite 8

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Reset
EXIT
TIME
DATE
SU WI
ON
PROG
OFF
MODE
INFO
The following switching programs are deleted
Time
00:00 Uhr
Date
01.01.2007
Summer time
EUROPA
Function
AUTO
Mode
V-AC (mains power)
Note: if a reset takes place in battery power mode, you must
re-select battery power mode under the MODE option.
Otherwise, the time clock will operate in mains failure mode and
the switching programs will not be executed.
Changing the battery
The device must be discon-
nected from the mains power
supply before dismantling the
module.
Replace the module before
reconnecting mains power to
the device.
Battery type: lithium cell CR2032
Manufacturer: Panasonic/Renata
High temperature type min + 70°C
In case of use other cells we don't assume any liability.
3
To avoid loss of
data, the battery
should be
replaced within
4
7 seconds.
Note: After fitting the module in BATT operating mode, it may take up to 1 hour
for the switching output to apply the module set state.
Hardware Reset
2
1
5
Permanent switching ON/OFF
EXIT
TIME
DATE
SU WI
PROG
ON = permanently switched ON
OFF = permanently switched OFF
For automatic operation, select AUTO.
Mains failure
If a mains failure occurs, the display is blank.
The relay state is maintained.
When mains power is restored, the display reappears after 5 seconds.
Press the 5-way switch (> 1 sec) to activate the display. The time
clock can then be programmed.
When mains power is restored, the switching program will be
executed according to the programs previously set.
Battery power
Mains power
EXIT
TIME
DATE
SU WI
PROG
In battery power mode BATT all the power is supplied
by the lithium cell. A mains power supply is not needed
in this case. The life of the lithium cell will be shorter in
battery power mode than in the factory setting of mains
power mode. Press the 5-way switch (> 1 sec) to ope-
rate. The switching programs will be executed and the
relay switches even without mains power. The sound of
the relay switching every hour is due to the refresh
(relay status is refreshed).
In mains power mode V-AC (factory setting) the dis-
play switches off if a mains power failure occurs. After
pressing the 5-way switch (> 1 sec) the time clock can
be programmed.
executed in mains failure mode.
When mains power is restored, the relay will switch
again according to the programs previously set.
The sound of the relay switching every minute is due to
the refresh (relay status is refreshed).
SU WI
PROG
TEST
AUTO
ON
PROG
TEST
AUTO
ON
OFF
= BATT
= V-AC
MODE
BATT
V-AC
TEST
AUTO
ON
OFF
MODE
The switching programs are not
ON
OFF
ON
OFF
OFF
ON