Herunterladen Diese Seite drucken

TFA 30.3048 Bedienungsanleitung Seite 9

Vorschau ausblenden Andere Handbücher für 30.3048:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
TFA_No_30.3048_Anleitung_10_16
TWIN – Wireless thermometer
• If the reception of outdoor temperature fails, "- -.-" appears on
the display. Check the batteries and try it again. Check if there is
any source of interference.
• Manual initialization can be helpful. Press and hold SEARCH
button of the basic unit for 3 seconds.
• A brief beep tone will sound, "- -.-" and the reception symbol
flash on the display. The basic unit will scan the outdoor tem-
perature.
7. Operation
• The instrument will automatically quit the setting mode if no
button is pressed within 15 seconds.
• Every press of a button is confirmed with a short beep.
7.1 Store and reset of the maximum and minimum values
• As soon as the basic unit and the outdoor transmitter are active
the maximum and minimum values for indoor and outdoor will
be stored and reset automatically after 24 hours.
• Press and hold SEARCH button for 3 seconds to clear the maxi-
mum and minimum outdoor values manually. At the same time
the reception for the outdoor transmitter will be activated.
• Press the RESET button with a pointed pin or remove the batter-
ies to clear all recorded values.
7.2 Temperature indication
• Press the ▼/°C/°F button to change between °C (Celsius) or °F
(Fahrenheit) as temperature unit.
7.3 Temperature alarm
• Press the ALERT button for 3 seconds.
and 70 °C (default) or the last adjusted upper temperature
limit appear on the display.
• Press the ▼/°C/°F or ▲ button to adjust the desired upper tem-
perature limit.
• Confirm with the ALERT button.
and -50 °C (default) or the last adjusted lower temperature
limit appear on the display.
• Press ▼/°C/°F or ▲ button to adjust the desired lower tempera-
ture limit.
16
25.10.2016
11:06 Uhr
Seite 9
TWIN – Wireless thermometer
• Confirm with the ALERT button.
• Press the ALERT button again, to activate the upper temperature
alarm.
appears on the right display.
• Press the ALERT button again to activate only the lower temper-
ature alarm.
appears on the right display.
• Press the ALERT button again to activate both alarms.
appears on the display.
• Press the ALERT button again to deactivate the alarm function.
disappears.
7.4 Case of alarm
• In the case of an alarm the corresponding symbol flashes
and an alarm sound is acitivated. You can stop the alarm by
pressing any button. If the alarm will not be turned off, the
instrument will automatically turn off after approximately 2 min-
utes.
7.5 Indication of frost
• If the outside temperature is between -2 °C and +3 °C the snow-
flake symbol appears on the display.
7.6 Positioning and fixing of the basic station and the transmitter
• With the foldable leg at the back of the basic unit it can be
placed onto any flat surface or wall mounted at the respective
location by the hanging hole at the back of the unit. Avoid the
vicinity of any interfering field like computer monitors or TV sets
and solid metal objects.
• With the foldable leg at the back of the transmitter it can be
placed onto any flat surface or wall mounted at the respective
location by the hanging hole at the back of the unit. Choose a
shady and dry position for the transmitter. (Direct sunshine fal-
sifies the measurement and continuous humidity strains the
electronic components needlessly).
• Check the transmission of 433 MHz signal from the transmitter
to the display unit (transmission range 30 m free field). Within
ferro-concrete rooms (basements, superstructures), the re-
ceived signal is naturally weakened.
17