Herunterladen Inhalt Inhalt Diese Seite drucken

Initial Start-Up; Automatic Cleaning; Manual Cleaning - clearaudio electronic double matrix professional SONIC Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

User manual / Bedienungsanleitung

6. Initial start-up

Filling the cleaning fluid reservoir
Place the funnel supplied into the filling hole (Pic. 2, No. 11, page 7) and fill the fluid reservoir with
Pure Groove
the
cleaning fluid provided (max. 0.4 l).
Pay attention to the LED level indicator so as not to over-fill. For effective cleaning we recommend
using only Clearaudio
Opening the cleaning and vacuum arm and placing the record
Lift the upper cleaning arm and swing it to the left to open the cleaning and vacuum assembly.
Turn the knob of the Seal record clamp anticlockwise to release the clamp then place the record to
be cleaned on the label-sized platter. Now put the
down gently while rotating the knob clockwise to secure the record in position and create a seal to
protect the record label from fluid damage.
Closing the cleaning and vacuum unit
Now you can swing the upper cleaning arm to the right to close the cleaning and vacuum assembly.

Automatic cleaning

The new features of the
provide fully automatic and efficient cleaning (see function 5.1, page 8). You only have to manually
activate the antistatic brush.

Manual cleaning

To set your own parameters for the cleaning process manually:
-
After you have placed and fixed the record with the
vacuum assembly.
-
Press the "Power" button to start the sonic cleaning function and rotation of the record.
-
Press the "Liquid" button to apply cleaning fluid to the record. Holding down the button for
longer applies more fluid. Adjust this according to the desired quantity of cleaning fluid.
-
After about 3 or 4 rotations, change the platter direction by pressing the "Platter" button.
We recommend 3 or 4 turns in each direction. By turning the "Platter Speed" knob you can
vary the rotational speed to further fine tune the cleaning process.
-
Once you are happy with the cleaning, press the "Vacuum" button. This will stop the sonic
cleaning function and start the vacuum drying process. After about 3 or 4 rotations, when the
record is visibly dry, switch off the suction by pressing the "Vacuum" button again.
-
Press the "Power" button to stop the record rotation.
-
Open the suction arm. Now start the antistatic function (see 5.3, page 21). After completion
of the antistatic function the manual cleaning is complete and you can remove your record.
Made in Germany
Pure Groove
cleaning fluid (available at www.analogshop.de).
double matrix professional SONIC
Seal
record clamp back on the spindle and press
"Auto", "Superclean" and "ECO mode"
Seal
record clamp, close the cleaning and
9

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Double matrixprofessionalsonic

Inhaltsverzeichnis