Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance - clearaudio electronic double matrix professional SONIC Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

User manual / Bedienungsanleitung

7. Maintenance

Changing the microfiber stripes
To change the microfiber stripes, remove the upper arm
of the cleaning and vacuum assembly by loosening the
side-mounted hex screw, then pulling the upper arm gently
upwards.
Next, release the microfiber supporters from the upper
and lower cleaning arms by applying a light pressure at
the end of each microfiber supporter, and then remove
them (see Fig. 4).
Now peel the old microfiber strips away from their
supporters. Before attaching new microfiber strips, it is
important to ensure that any grease, dust or residual
glue from the old microfiber strips is removed from the
microfiber supporter.
Apply new microfiber strips, firmly pressing them onto the supporters.
We recommend changing the microfiber strips after approx. 100 cleaning programs, though this will
depend on the condition of the records cleaned.
Cleaning and draining the waste fluid tank
Over time it is possible for residue to settle in the waste fluid tank which could potentially block the
drain tube. To avoid this happening you should periodically clean the waste fluid tank.
1.
Remove the upper suction arm after loosening the side-mounted screw and pulling it gently
and steadily upwards.
2.
Place the filling funnel into the suction tube.
3.
To flush the waste tank, we recommend 250 ml warm water, which you pour in the waste
tank.
4.
Let the warm water sit in the waste tank for approximately 20 minutes, then drain it by re
moving the sealing plug from the drain hose and put the end of the drain hose into a bowl
(etc.) which is positioned deeper. Repeat this process until the drained flushing water is clean
and does not contain any reside.
Please note:
If you take the machine into operation again, the drain tube must always be closed by
the stopper, so that the vacuum pump can generate the required vacuum for suction.
Only through this we can guarantee a lasting and full function of your cleaning machine.
The drain tube at the rear should not be pusehd back into the machine. This could bend
the tube and the leaking fluid could damage the cleaning machine.