Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Considerations; Technical Data - Dustcontrol DC 3800c Turbo Betriebsanleitung

Vorschau ausblenden Andere Handbücher für DC 3800c Turbo:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Safety Considerations

Read all instructions before attempting to operate this
machine and save these instructions.
Warning! When using electric machines, basic safety
precuations should always be
the risk of fi re, electric shock and personal injury,
including the following:
1. Work area environment
Don´t expose the machine for rain. Don´t use
it in damp or wet locations or in presence of
fl ammable liquids or gases.
2. Overload
Never let the machine operate fully throttled.
Always follow the regulations pertinent to the
material you are working with ie asbestos.
Don´t use the machine for purposes that it isn´t
intended for.
3. Body injuries
Never let the suction come in contact with
parts of the body. The strong suction effect can
hurt the blood-vessels in the skin. Do not re-
pair the electric components yourself, get
somebody qualifi ed. Faults may cause injury.
See also below under warnings.
4. Don´t abuse cord
Never pull the machine by cord. Keep cord

TECHNICAL DATA

HxWxL
Weight
Inlet
Hose length
Collection in container
Flow, max
Neg. pressure, max
Power consumption
Fine fi lter polyester, area
Degree of separation
EN 60335-2-69, class M
Filter area microfi lter
Degree of separation
microfi lter, EN 1822-1
EN 60335-2-69, Klass H
Soundlevel
2008-02-19
followed to reduce
50 Hz
60 Hz
1400x600x970 mm
62 kg
62 kg
X 50 mm
X 50 mm
5-15 m
5-15 m
40 l
40 l
3
3
260 m
/h
320 m
/h
28 kPa
31 kPa
2.5 kW
3 kW
2
2
1.8 m
1.8 m
> 99.9 %
> 99.9 %
2
2
1.5 m
1.5 m
HEPA H13 HEPA H13
99.995 %
99.995 %
< 75 dB(A) < 75 dB(A)
DC 3800c Turbo - 8
from heat and sharp edges. Check the electric
cable regularly if damage.
5. Important measure
With cleaning and maintenance on the mach-
ine, the power cable should be disconnected
from the supply.
6. Maintain the machine with care
Keep machine clean and check that the hose
is entired and that all gaskets are tight. Follow
instructions. Keep handles dry and free from
oil and grease.
7. Checking of damage
Before futher use of the machine it should
be carefully checked that the machine is un-
damaged. If there are any damaged parts these
should be repaired by of a Dustcontrol authori-
zed service center.
8. Warning
Use only accessories and replacable parts
which are available in Dustcontrol catalogue.
When using faulty parts or pirate parts
(especially fi lter) the machine could leak out
unhealthy dust which can cause personal
injuries.
Capacity
kPa
20
10
DC 3800
2.2 kW 50 Hz
100
200
DC 3800 3.0 kW 60 Hz
3
300
400
m
/h
Art nr 94131