Plan View - Falcon toledo FS Gebrauchs- Und Wartungsanleitung

Doppelofen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fitting the stability bracket
The appliance is front heavy when the doors are
opened so the rear needs to be fixed to the floor. A
stability bracket is included with the appliance for
this purpose. It is not sufficient to rely on the worktop
as a downward force on the oven doors could cause
the worktop to crack.

Plan View

KITCHEN WALL
400mm
L.H
Cabinet
500mm
Front edge of door will align
Door Front
with appliance side trim front
or
A
B
1.
Fix the stability bracket to the floor in the position
shown in the attached diagram. When the doors are
opened quite a large force can be levered onto the
bracket. It is essential to ensure the screws are firmly
held using Rawl type plugs where necessary.
2.
Set the height of the top arm so that it is higher than
the appliance rear member.
Electrical Connection
This appliance must be installed by a qualified
electrician to comply with the relevant Institute of
Electrical Engineers (I.E.E.) regulations and also the
local electricity supply company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED
Note
The appliance must be connected to the correct
electrical supply as stated on the voltage label on
the appliance, through a suitable cooker control unit
incorporating a double pole switch having a contact
separation of at least 3mm in all poles. This appliance
must not be connected to an ordinary domestic
power point.
Check the appliance is electrically safe when you have finished.
400mm
A
B
500mm
are positions for bracket
INSTALLATION
The unit is fitted with a mains cable to facilitate
R.H
Cabinet
connection to a wall point. If the cable needs to be
changed then access to the mains terminal is gained
by removing the electrical terminal cover box on
the back panel. Connect the replacement cable to
the correct terminals for your electrical supply type.
Check that the links are correctly fitted and that the
terminal screws are tight. Secure the mains cable
using the cable clamp. Ensure the cable route avoids
the risk of trapping or touching hot surfaces such as
the underside of the hotplate.
Current Operated Earth Leakage Breakers
Where the installation is protected by a 30 milliamp
sensitivity residual current device (RCD), the
combined use of your appliance and other domestic
appliances may occasionally cause nuisance tripping.
In these instances the kitchen circuit may need to be
reconfigured. This work should be carried out by a
qualified electrician.
Levelling
The worktop should already be fitted and levelled,
and the cabinets mounted 90 degrees to the
worktop. It is therefore only necessary to ensure the
top front edge of the appliance unit supports the
front edge of the worktop and line up the appliance
trims with the doors as follows.
1) Ensure gas pipes and electrical cable will not be
trapped by the appliance when it is pushed into
position.
2) Place the appliance in its intended position taking care
not to twist it within the gap between the kitchen
units as damage may occur to the appliance or the
units.
3) Ensure the stability bracket top arm is above the rear
channel. See diagram.