• Elektronic functions
Function
description
remove label and
- until waterfl ow starts - start of automatic sensor adjustment
fi rst startup
wait for 15 sec. - keep out of senor area
(waterfl ow approx. 6 sec. and sensor adjustment)
(0.5 - 5cm) waterfolw starts and sensor area increase (0.5 - 20cm)
Normal function
(water fl ow)
if no
follow up time control
1 x for 5 sec. until
for normal operation
1 x until desired follow up time is reached
set / programm
temporary off
2 x - confi rmation of function via
„cleaning mode"
activate
pulsates while „temporary off" is activated
1 x
temporary off
stop
or automatic after preset time
1 x for at least 2 sec. (max. 5 sec.)
continous run
waterfl ow starts and
activate
run" mode (
1 x
continous run
stop
oder or automatic after preset time
time of waterfl ow for
1 x minimum 2 sec. (max. 5 sec.) and release - start waterfl ow
continous run
1 x - and hold - after 5 sec.
and
purge duration of line
has reached (
purge feature
confi rmation of setting by repeating number of
set / programm
1 x - and hold - after 24 sec.
line purge feature
has reached
activate / deactivate
„automatic fl ush on set
1 x= off,
intervall"
duration of line purge = time of waterfl ow for continous run
2x -
1 x for 5 sec. until
restart electronics
wait for 20 sec. - keep out of senor area
(after approx. 10 sec. - waterfl ow for approx. 6 sec. and sensor
adjustment)
2x -
1 x and hold - after 5 sec.
when desired sensor range has reached (
sensor range
set / programm
wait for 20 sec. - keep out of senor area
(after approx. 10 sec. - waterfl ow for approx. 6 sec. and sensor
adjustment)
after approx. 90 sec.
security off
(if
permanent)
stopped - additional a automatic sensor adjustment will be started
empty battery
when
6
... press click-button
... hand/objekt within sensor area
... fl ashing of LED (green/red)
1 x
for approx 3 sec., sensor area decrease (0.5 - 5cm)
1x - release button
-
indicates time of waterfl ow at „continous
1 x = 30 sec. „continous run" - time of waterfl ow)
1x-40x - release when desired time
1 x = 30 sec. time of waterfl ow)
1x-4x - release when desired time
2 x= 12h,
3 x= 24h
pulsates
4x - release
pulsates
4 x - hold on until
permanent detection the waterfl ow will be
, fl ushing instead of waterfl ow
3 x
- according to setting
1x-8x - elease
1x= min ...
8x= max.)
setting
range
default
via push
button
required if new
-
automatically
-
1 sec.
0-10 sec.
2 min.
-
0 -20 min.
2 min.
in 0.5 min.
steps
off
off
12h
24h
manually
-
6
1-8
on
-
automatically
-
setting
range via
service-pc
activation of
factory setting
manually
0-3600 sec.
0-3600 sec.
0-3600 sec.
0-5000h
manually
1-8
-
voltage -
information
74.074.EU15