Herunterladen Inhalt Inhalt Diese Seite drucken

Button Functions; Operation - VOLTCRAFT CM-100 Bedienungsanleitung

Co2-messgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Button Functions

POWER
Power switch; to switch the unit on and off
HOLD/ESC
Measuring operation: The measured values can be held in the display by pressing the
HOLD button.
Setup Menu: The menu is exited by pressing the ESC button. The parameters are not
saved.
REC/ENTER Measuring operation: The Min-/Max measured values are saved by pressing the REC
button, and every additional press of the button displays the Min/Max values one after
the other.
Setup Menu: The parameter input will be saved (ENTER). The menu is then exited.
SET/S
Opens the setup menu (SET). In the setup menu, allows you to switch forwards between
menu items (S) and to change the parameter values (up).
ALARM/F
Activates the alarm mode (ALARM). In the setup menu, allows you to switch backwards
between menu items (F) and to change the parameter values (down).
Initial Operation
Inserting the batteries
Before the initial operation of this meter, you must first install six new micro-batteries (alkaline AAA). A
power pack unit can be used optionally. Battery insertion and power pack operation are described in the
"Maintenance and Cleaning" section.
Connecting the measuring sensor
Connect the round plug of the sensor (15) with the socket "PROBE INPUT" (6) on the measuring device.
The plug is protected against wrong polarity and only fits into the socket in the right direction. Observe
the arrow marking on the plug. This marking points towards the back of the device. Make sure that the
plug is firmly inserted otherwise inaccurate measurements will be made.
Setting up the measuring device
For better reading, the measuring device can be set up using the bracket on the rear (12).
The device can be mounted on a tripod using the tripod socket (14)
Automatic cutoff function
In order to avoid that the operating life of the battery is shortened unnecessarily, an automatic switch-off
function has been implemented. The device is automatically switched off if no button has been pressed
over a period of about 10 minutes. You can switch the device back on with the "Power" button (3).
The automatic cutoff function be turned on/off within the setup menu (PoFF). The setup menu is
explained in the next chapter. This function is always deactivated in the REC mode.