Use with the internal heating control
Connecting will be made via a 230 V AC power supply. The HEATSCOPE® heater will be connected with the electronical device of the engine.
With help of the inegrated power metering the LIFT will be driven out when power is going over >0.5 A. If the heater is turning off, the LIFT will be
driven in the ceiling recess again after a cooling down time of 180 sec.
Use with an external heating control
If the heating elements are controlled externally (thermostat, BUS system like KNX etc.), the LIFT control system can be used as well. Additionally a
power cable for both heating groups is mandatory. The measurement of the power of both heating groups will be made separately. If the power
of one of the heating elements is going over >0.5 A the integrated power metering will drive out the LIFT lifting system automatically. If no power is
measured on both heating elements, the LIFT will be driven in after 180 sec. waiting/cooling time. If the heating elements are running with a pulse rate,
the 180 sec. will start over and over again.
Technical Data
art. no.
MHS-LFT // MHS-LIFT // MHS-VS-LIFT
power
24 V DC
engine
linear electronic lifting cylinder, 24 V DC
max. engine power
1,5 A
measuring circuit
2 power circuits, max. 230 V 16 A, one phasis
ambient tempe-
-10° C up to +50° C
rature ta
humidity
1-85% r.F. non-condensing
connection
screw terminal max. 2,5 mm², pluggable
dimensions
53x90x59 mm = 3 TE
(WxHxD)
IP class
IP 30
CE standard
yes