Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Characteristic Data - Balluff BES 516-300-S266-S4 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BES 516-300-S3 _ _ -S4-N
Inductive Sensors

Installation

<0.02
Thread undercut D DIN 76
0.6 x diameter of O-ring cord
BES 516-300-S332-S4-N
A
≥12.5
≥9
0.1 A
Technical data

Characteristic data

Eff. switching distance S
r
Rated switching distance S
n
Repeat accuracy R
max
Electrical data
Nominal voltage
Current consumption, undamped
Internal capacitance C
i max
Internal inductance L
i max
Polarity reversal protected
www.balluff.com
L
Mounting direction
Mounting direction
Ra 6.3
Ra 3.2
1.5 mm
1.5 mm
5 %
8.2 V DC
4 mA
min
30 nF
0.5 mH
yes, up to 9 V
Ignition protection type "ia"
Example: BES 516-300-S315 -S4-N
d1: Diameter of bore for switch head
e. g: Ø 10
=Ø 10
H8
+0.022
d2: Rated thread diameter
e. g. M12x1 6H
L:
Recommended screw-in depth in steel L 0.8xd2
0.8x12=9.6
To ensure sealing under extremely high pressure, switches
are equipped with O-ring and Teflon support ring
Mechanical data
Housing material
Connection type
Degree of protection as per
IEC 60529
Only operate with a suitable, approved isolating
amplifier or processor if the following maximum
values are not exceeded: U
P
 = 120 mW.
i
For further technical data see data sheet.
Intrinsically safe
Stainless steel: 1.4104
M12 connector, 4-pin
Conforms with:
EN 60079-0/-11
II 2 G Ex nA
IP68 according to
BWN Pr 20
 = 15 V; I
 = 50 mA;
i
i
english