Operation

General operation
• The device can be operated directly via the display. It can be operated either directly as a touch-
screen or by means of the supplied stylus.
• To open a menu item, simply tap on it.
Alternatively, you can use 4 direction keys to select the item (green bar). Confirm here with the
"OK" button.
This also applies to submenus and data input.
• To quit a menu item, tap at the bottom right on "Esc" or "Return".
As an alternative, to quit the menu item you can press the right direction button in the menu
"Record" and "Clock".
• In the menu "Settings", where you change, set or select a value, always select "Save" to save it,
and "Return" to quit.
Menu overview
"Record"
Shows the saved measurements, which are performed under the menu item "Test".
"Test"
An extensive alcohol test is performed. The result can be recalled later under the
item "Record".
"Quick"
A rapid test is performed.
"Alco cal." This item is only important for factory calibration.
"Clock"
Indicates the set time and date.
"Settings"
To open this item, you must enter the password 20131205 and confirm with "Ok".
"Date&Time Setting"
Here, the date and time can be set. Tap, best of all with the stylus, on the value (e.g.,
year) you want to adjust. It will turn green. Then tap in the proper value. Once you
have set the date and time, tap on "Save" to save them. Tap on "Return" to quit.
"Power Off Time"
Here, you can set period after which the device will switch off automatically if no
operation is performed. Set time simply by tapping on + or - .
"Alarm Level"
Here you can set the value at which the device triggers an alarm signal when testing.
Set the desired value simply by tapping on + or - .
"Alcohol Unit"
Here you can set the units of alcohol (mg/100 ml; %; ‰; mg/L). Set the desired unit
simply by tapping on + or - .
"mg/l' setting"
Here you can change the setting for convention ratio (mg/L / permille). Possible val-
ues: 2.0; 2.1; 2.2; 2.3
"Touch Calibration"
Tap four times by the stylus on the green on the green dot in the four corners. It will
be saved automatically.
"Parameter"
Displays system information.
Carrying out an alcohol test
Before an alcohol test, a person should not smoke, eat or drink anything during 15 min-
utes preceding the test.
Otherwise, the test results could be distorted and alcohol tester damaged!
Other things that may distort the test results are e.g., spirit-based oral sprays, medi-
cines and drops, as well as vomiting and belching.
If the capacity of the rechargeable battery is less than 25%, charge it before starting
the test.
• Before the test can be started, the person to be tested should first rinse mouth with water or a
non-alcoholic beverage.
• Switch on the alcohol tester. The battery must be charged and a new or cleaned mouthpiece
inserted. Set all desired settings such as time or measuring units beforehand.
• Your can perform either a rapid test or a detailed official test.
Rapid testing
• Open the item "Quick" in the main menu.
• Let the person to be tested blow into the mouthpiece until the alcohol beeps or clicking sound is
heard.
• The result will appear on the display.
• In addition, there is a possibility of performing a test without the need for the person to be tested
to blow into the device. It can be useful e.g., when a person is already heavily drunk. In this case,
it is enough to keep the alcohol tester in the vicinity of the mouth or nose of the person to be
tested.
Then press the "OK" button on the device to initiate the test. And again, the result will appear on
the display.
Detailed testing
• Open the item "Test" in the main menu.
• Please in turn: name of the driver; license plate; place; driver's ID; name of the testing person.
Confirm individual entries by "Ok" on the touchscreen. Thus, you will move to the next entry. At
that, input is done with letters and numbers on the touchscreen. If you do not wish to complete
fields, just skip them with "OK" on the touchscreen.
• Once "Ready" and "Please Blow" appear on display, let the person to be tested blow into the
mouthpiece for about 6 seconds. The alcohol tester will beep at the same time. Once the beep
tone sounds, the test is completed. A clicking sound is also heard then.
• The result will appear on the display. Besides, it will be automatically saved and can be recalled
in the menu item "Record".
If blowing into mouthpiece has been too short, the beep tone will be heard and the
message "Blow too Short" will be displayed. Then tap on the "Retest" and repeat the
test.

Maintenance and cleaning

• The product does not require any maintenance.
• The product exterior should be cleaned only with a clean, soft, dry cloth. Do not apply too much
pressure on the display, as it may crack.
• Clean the used mouthpieces with hot water a some washing-up liquid after every use.
Do not use abrasive cleaning agents, or other chemical solutions, since these could
damage (discolour) the housing or even impair operation.
Disposal
a) Product
The product must not be disposed of in household waste!
Dispose of the waste product in accordance with the applicable legal regulations.
Remove the inserted batteries or rechargeable batteries and dispose of them separate-
ly from the product.
b) Batteries and rechargeable batteries
As the end user, you are required by law (Battery Ordinance) to return all used batteries/recharge-
able batteries; disposal of them in the household waste is prohibited!
Batteries/rechargeable batteries contain harmful materials and are labelled with the
symbol shown to indicate that disposal in the household waste is forbidden. The sym-
bols of the relevant heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead (marking can
be seen on the battery/rechargeable battery, e.g., underneath the refuse bin symbol
shown on the left).
You can return your used batteries/rechargeable batteries free of charge at the official collection
points of your community, in our stores, or at places where batteries or rechargeable batteries
are sold!
You thereby fulfil your statutory obligations and contribute to the protection of the environment.

Declaration of conformity (DOC)

We, Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this
product conforms to the fundamental requirements and other relevant regulations of the 1999/5/
EC directive.
The Declaration of conformity for this product is available at www.conrad.com

Technical data

Power supply .......................................rechargeable battery/USB
Operating voltage USB.......................5 V/DC, 500 mA (for charging)
Battery ..................................................rechargeable Li-ion battery, 3.7 V/DC, 800 mAh
Indication..............................................TFT 2.4'' QVGA with a touchscreen
Measuring range.................................0.0‰ to 4.0‰ (BAC in permille); ± 0.05‰ (at calibration point)
Measuring units ..................................mg/100 ml; %; ‰; mg/L
Measuring method..............................fuel cell technology
Memory.................................................for max. 3000 measurements with ID and time specification
Warm-up time ......................................approx. 10 s (without residual alcohol)
Calibratable ..........................................no
Dimensions (H x W x D)......................approx. 128 x 62 x 30 mm (without a mouthpiece)
Weight ...................................................approx. 151 g (with a battery)
USB cable lenght ................................approx. 50 cm
Operating conditions ..........................+5 °C to +45 °C; 30% to 90% relative humidity
Storage conditions..............................0 °C to +55 °C; 30% to 90% relative humidity
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis