Balluff BUS M30M1-PPX-03/025-S92K Bedienungsanleitung Seite 7

Ultraschall sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

...or with the Teach-in procedure
Teach-in swítched output
Usefull additional functions in Add-on menu (settings not required for standard applications)
Start here
T1 + T2
Press T1 and T2 simultaneously for about 13 s
until »Add« is shown in the LED-display
T1
T2
T1
T1 + T2
T1 + T2
T1
T2
T1
T1 + T2
T1 + T2
T2
T1
T1 + T2
»C01«: Display
Minimum value:
bright
»001«
Ready
»C02«: Display dim-
Maximum value: dif-
med
ference between
maximum range and
»C03«: Display off
detect point - 1
During window
mode operation hys-
teresis influences
Note
both detect points.
Changes in the Add-on
menu may impair the
sensor function.
A6, A7, A8 , A10 , A11,
A12 have influence on
the response time of
the sensor.
Low power mode
Hysteresis
switched output
Adjust detect point
Adjust window mode
Place object at position
Place object at position
Press T2 until »d« is shown
Press T2 until »d« is shown
Current measu-
Current measu-
ring value
ring value
Place object at position
Current measu-
ring value
Press T2 until »End« is
Press T2 until »End« is
shown
shown
Normal mode operation
T1
T1
T1
T2
T2
T2
T1 + T2
T1 + T2
T1 + T2
T1
T2
T1
T2
T1
T2
T1 + T2
T1 + T2
T1 + T2
»F00«: no filter
Defines the strength
Delay in seconds
of the chosen filter.
between the detec-
»F01«: standard fil-
tion of an object
ter
»P00«: weak filter
and the output of
up to
»F02«: averaging fil-
the measured dis-
ter
»P09«: strong filter
tance in case of ob-
ject approach (beha-
»F03«: foreground
ves as on-delay).
filter
"00": 0 s (no delay)
»F04«: background
up to
filter
"20": 20 s response
time
Measurement filter
Filter strength
Response time
Adjust two-way reflectiv
Set NOC/NCC
barrier
Place reflector at position
Press T2 until countdown
passed from »- 8 -« to »- 0 -«
Press T2 until »d« is shown
and NOC or NCC symbol is
displayed
Current measu-
Symbol
ring value
NOC or NCC
Press T2 until countdown
To change output function
passed from »- 8 -« to »- 0 -«
press T2
and »End« is displayed
Symbol
NOC or NCC
Press T1 and T2 simultane-
ously until »End« is dis
played
T1
T1
T2
T2
T2
T1
T1 + T2
T1 + T2
T1 + T2
T2
T1
T2
T1
T2
T1
T1 + T2
T1 + T2
T1 + T2
Minimum value:
»00«: synchronisati-
To optimize multi-
blind zone
on
plex speed the hig-
hest sensor address
Maximum value: ne-
»01« to »10«: sensor
may be set.
arwindow limit - 1
address for multi-
plex mode
Setting range »01«
to »10«
»oFF«: synchronisati-
on deactivated
Foreground
Multiplex mode
Multiplex mode
suppression
device addressing
highest address
T2
T1
T2
T1
T2
T1
T1 + T2
T1 + T2
T1 + T2
T1
T1
T2
T2
T1
T2
T1 + T2
T1 + T2
T1 + T2
Minimum value: sen-
Put plane reflector
Affects the size of
sor-distant window
vertically disposed in
the detection zone.
margin
front of sensor: in
»E01«: high
an exact distance of
Maximum value:
250 mm for BUS
»E02«: standard
999 mm for
M30..-03/25-.. and
»E03«: slight
BUS M30..-03/025-..,
BUS M30..-07/035-..
BUS M30..-20/130-..,
and 900 mm for all
999 cm for
other typs.
BUS M30..-07/035-..,
Adjust display to
BUS M30..-35/340-..,
250 mm or 900 mm.
BUS M30 ..-60/600-..
Confirm calibration
with T1 + T2.
Measurement range
Calibration
Detection zone
display
sensitivity
Key lock and factory setting
Activate/deactivate
Reset to factory set-
TouchControl
ting
Turn supply voltage
Turn supply voltage
OFF
OFF
Turn supply voltage
While pressing T1
ON while pressing T1
turn supply voltage
and keep it pressed
ON until »on« or
for ca. 15 s until
»off« is displayed
»rESEt« has passed
through the display
»on« or
»off«
To activate or
deactivate press T1
»on« or
»off«
To activate or
deactivate press T1
Normal mode operation
T2
T2