Product description
The BUS M30 sensor with one switched
output measures the distance to an ob-
ject within the detection zone contact-
less. Depending on the adjusted detect
distance the switched output is set.
All settings are done with two push-but-
tons
(TouchControl).
Light emitting diodes (three-colour LEDs)
indicate the switching status.
Instruction manual
The output functions are changeable
from NOC to NCC.
BUS M30 Ultrasonic Sensor
The sensors are adjustable manually using
the numerical LED-display or may be trai-
with one switched output
ned using Teach-in processes.
Useful additional functions are set in the
BUS M30M1-PPX-03/025-S92K
Add-on-menu.
BUS M30M1-PPX-07/035-S92K
BUS M30M1-PPX-20/130-S92K
BUS M30M1-PPX-35/340-S92K
BUS M30M1-PPX-60/600-S92K
Set sensor parameters alternatively numerically using LED-display...
Important instructions for assembly and
application
All
employee
measures must be taken prior to assembly,
start-up, or maintenance work (see operation
manual for the entire plant and the operator
instruction of the plant).
The sensors are not considered as safety
equipment and may not be used to ensure
human or machine safety!
The BUS M30 sensors indicate a blind zone,
and
a
three-digit
LED-display
in which the distance cannot be measured.
The operating range indicates the distance of
the sensor that can be applied with normal
reflectors with sufficient function reserve.
When using good reflectors, such as a calm
water surface, the sensor can also be used up
to its maximum range. Objects that strongly
absorb (e.g. plastic foam) or diffusely reflect
sound (e.g. pebble stones) can also reduce
the defined operating range.
T1
T1
For single detect
point press T2
T2
until »- - -« is
displayed
T1
Set switched output
T2
Synchronisation
If the assembly distances shown in Fig.1 for
and
plant
safety-relevant
two or more sensors are exceeded the inte-
grated synchronisation should be used. Con-
nect Sync/Com-channels (pin 5 at the units re-
ceptable) of all sensors (10 maximum).
A
≥ 0.35 m
≥ 0.40 m
≥ 1.10 m
≥ 2.00 m
≥ 4.00 m
Fig. 1: Assembly distances, indicating syn-
chronisation/multiplex
Multiplex mode
The Add-on-menu allows to assign an indivi-
dual address »01« to »10« to each sensor
connected via the Sync/Com-channel (Pin5).
The sensors perform the ultrasonic measure-
ment sequentially from low to high address.
Therefore any influence between the sensors
is rejected.
Start here
T1 + T2
Press T1 and T2 simultaneously for about
3 s until welcome message has passed
T2
T1 + T2
Set detect distance in
T2
mm or cm
T1 + T2
For window mode
operation set far
T2
T1
detect point in
mm or cm
T1 + T2
Choose »
« for NCC or
T2
»
« for NOC
T1 + T2
T1
T1 + T2
Ready
The address »00« is reserved to synchronisa-
tion mode and deactivates the multiplex
mode. (To use synchronised mode all sensors
must be set to address »00«.)
Assembly instructions
B
Assemble the sensor at the installation lo-
cation.
≥ 2.50 m
Plug in the connector cable to the M 12
≥ 2.50 m
connector.
≥ 8.00 m
≥ 18.00 m
≥ 30.00 m
2
1
3
5
4
colour
1
+U
brown
B
3
0 V
blue
4
Out
black
2
-
white
5
Sync/Com.
grey
Fig. 2:
Pin assignment with view onto sen-
sor plug and colour coding of the
Balluff connection cable
Start-up
BUS M30 sensors are delivered factory made
with the following settings:
Switched output on NOC
Detecting distance at operating range
andhalf operating range
Measurement range set to maximum ran-
ge
Set the parameters of the sensor manually or
use the Teach-in procedure to adjust the de-
tect points.
measuring range
c
m
m
m
%
3-digit
LED-display
LED D1 and D2
Push-buttons T1 and T2
T
1
D
1
D 2 T 2
Fig. 3: TouchControl
Operation
BUS M30 sensors work maintenance free.
Small amounts of dirt on the surface do not
influence function. Thick layers of dirt and
caked-on dirt affect sensor function and the-
refore must be removed.
Note
BUS M30 sensors have internal tempera-
ture compensation. Because the sensors
heat up on their own, the temperature
compensation
reaches
its
optimum
working point after approx. 30 minutes
of operation.
During normal mode operation, a yellow
LED D2 signals that the switched output
has connected.
During normal mode operation, the mea-
sured distance value is displayed on the
LED-indicator in mm (up to 999 mm) or
cm (from 100 cm). Scale switches auto-
matically and is indicated by a point on
top of the digits.
During Teach-in mode, the hysteresis
loops are set back to factory settings.
If no objects are placed within the detec-
tion zone the LED-indicator shows »- - -«.
If no push-buttons are pressed for 20 se-
conds during parameter setting mode the
made changes are stored and the sensor
returns to normal mode operation.
You can lock the key pad to provide in-
puts, see »Key lock and factory setting«.
You can reset the factory settings at any
time, see »Key lock and factory setting«.
Show parameters
Tapping push-button T1 shortly during nor-
mal mode operation shows »PAr« on the
LED-display. Each time you tap push-button
T1 the actual settings of the switched output
are shown.
2004/108/EC