• Media temperature during operation: maximum of 50°C.
• Media temperature during downtime: maximum of 70°C.
• Ambient temperature between 5°C and 70°C.
• Considerable to strong vibrations and shocks.
3.1 Connection to pipeline
NOTICE
Formation of air bubbles in the meter results in incorrect measurements
• Do not install the meter at the highest point in the pipeline.
• During operation, the pipeline must always be fully filled.
NOTICE
Incorrect installation position may result in incorrect measurements
•
Comply with the specified installation position.
Facing upwards or to the side
NOTICE
Property damage due to pressure shocks in the pipeline
• When installing the meter, ensure that the meter is not subjected to any
pressure shocks within the pipeline.
NOTICE
Property damage as a result of water leaks due to used seals.
• When installing the meter, ensure that the meter is not subjected to any
pressure shocks within the pipeline.
NOTE
For a smooth installation, comply with the following measures:
• Do not abruptly reduce/increase the pipeline cross-section before and
after the meter.
• No inlet and outlet sections required (U0D0).
• Changes in the cross-section should be concentric at an angle of <8°.
• Use thread seals such as sealing compound suitable for potable water,
hemp or teflon.
• Install flow regulators after the meter in the flow direction.
RUBIN HYZ ST, RUBIN HYZ RS
Meter head
Pipeline
Horizontal
Vertical
41