INSTALLATION INSTRUCTIONS – CONTROL PANEL 3020 013
Control panel 3020 013 is intended for the Alde Compact 3020 boiler.
The control panel should be located at least one metre above the fl oor, but not too close to the ceiling. Nor should it be
located on an outer wall or close to items which radiate heat, such as a CD player, refrigerator or lamps, as this may
result in incorrect temperatures. The space behind the panel should be well ventilated. If the room thermostat on the
panel is still affected, an external sensor should be connected to the panel.
Make a hole for the control panel as shown in Figure C. Screw the control panel securely in place and push the front
cover into position. Secure the cable with clamps to prevent any strain on the terminal strip of the panel.
A.
86 mm
CABLE CONNECTION BETWEEN BOILER COMPACT 3020 AND CONTROL
PANEL 3020 013
Connect accessories to the control panel as shown in the diagram below. NB! Do not clamp 12 V cables or sensor
cables together with 230 V cables. It is best not to position the cables close to one another. If the cables are bundled
together, there is a greater risk of malfunction during operation.
Control panel rear
18
B.
9 mm
External room sensor 1
External room sensor 2
Battery back-up (3 V DC)
EXT
38,5 mm
+
C.
76 mm
73 mm
R3(4x)
Boiler
TIN Bus