16. *Booster
This function allows you to set two different
speeds for a booster (if installed) and to con-
trol start-up and shutdown of the fan from the
panel. If the boiler's circulation pump starts
up, the fan on the booster will as well. When
the circulation pump stops, the fan will con-
tinue to run for another six minutes, and also
then stops unless the circulation pump has
started up again, i.e. giving automatic control
of the booster fan. NB! A booster has to be
installed if this function is to be used (see
the manual for the vehicle, boat or build-
ing).
17. *Settings room sensors
This function allows you to select which sen-
sor is to be active. The setting you make can
determine, for instance, whether the sensor
located in the living quarters, sleeping quar-
ters or the panel should be active. If Auto is
selected, the sensor in the panel is active and
will automatically switch to the remote sensor
if one is connected. You can select settings
from: Auto, Ext. sensor 1, Ext. sensor 2 and
Panel sensor.
In Auto mode
No external sensor is connected
= The panel sensor is active.
One external sensor is connected (1 or 2)
= The external sensor is active.
Two external sensors are connected (1 and 2)
= External sensor no. 1 is active.
NB! External sensors have to be installed
(there is always one sensor in the panel) if
this function is to be used (see the manual
for the vehicle, boat or building)
10. Service and resetting the system
1
Service
2
Reset
3
Translator
16
1. Service
This function allows you to see
some of the boiler values on the
screen. The values are updated
every second.
A
2. System reset
4
OK
This function is for resetting the
panel to its factory settings. After
a reset, the panel is set as follows:
Boiler – Off mode; electrical opera-
tion – 1 kW; LPG heating – On
mode; indoor temperature – 22°C.
Other functions are switched off.
18. Locking of the tools menu
The tools menu is locked by selecting the
closed padlock.
19. Activated functions (A)
This page shows the various functions which
have been activated (e.g. Automatic tempera-
ture change). You can also press the buttons
on this page to access the relevant activated
function directly and effect new settings or
switch it off.
20. OK
OK
To exit the tools menu, press OK or Menu.
3. Translator
This function is used to enable an
external main panel to operate the
boiler. If a main panel is connected
to the Alde panel, it is activated
with the On button, otherwise the
latter must always be set at Off.
The factory setting is Off.
4. OK
To exit the tools menu, press OK
or Menu