The connected battery is deeply discharged (<10.5 V).
The battery has reached 25% of the charge capacity.
The battery has reached 50% of the charge capacity.
The battery has reached 75% of the charge capacity.
The battery is fully charged and can be disconnected from the charger.
Flashing: The charger has started a desulphation process.
A deeply discharged battery has been detected and is being gently pre-charged.
Error messages
The battery has been connected with the terminals reversed. Switching the
charging clamps (polarity).
The battery is faulty.
The charger is overheated.
The battery has been deeply discharged and no longer takes on any voltage.

4. Features

• 7-stage charging process
• Selectable charging current: 1000 mA max. for motorcycle mode and 4000 mA
max. for car mode
• Automatic charging voltage adjustment with multi-stage charging characteristic
(I-phase, U1/U2-phase)
• Suitable for 12 V (6 cells) lead-acid, lead-gel, lead-fleece (AGM), calcium and
pure lead vehicle batteries
• Suitable for 12 V Li-ion vehicle batteries
• CAN bus enabled
• Special charging mode for cold ambient temperatures or for charging AGM
batteries
• Battery test function
• Desulphation function* for sulphated batteries
• Regeneration function* for deeply discharged batteries
26
Chase light: A sulphation check is in progress.