Herunterladen Inhalt Inhalt Diese Seite drucken

Sequential" - Random Flow - Tunze 7096 Gebrauchsanleitung

Multicontroller
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

„Sequential" - random flow

Random flow is produced when sequential pump operation and pulse operation are switched on at the
same time. It develops always when a fixed "pulse flow" or "random flow" pulse frequency is set.
Click the "Sequential" button in the "Mode" field.
Set the "Sequential" switching time by clicking 1 to 10 seconds.
Click „Power 1" and „Power 2" pump outputs in the „Power control" field to set channels 1 to 4. Figure
"0" indicates that the pump is not operational. The smallest possible setting is 30 per cent which can be
increased to 100 per cent.
Set the "Pulse flow" pulse frequency from 0.30 to 8.00 seconds.
Result:
The pumps connected up to the ports 1, 2, 3 and 4 operate randomly, producing an irregular flow pattern.
When activated, the "Night mode" function interrupts the random flow operation as soon as the aquarium
lighting goes off; all pumps remain in "Power 1" setting permanently. In the morning when the light is
switched on again, the pulse operation will start again.
When activated, the "Wavecontroller" function uses the outputs 3 and 4 whilst the "Sequential" random flow
is active only for outputs 1 and 2.