Programming Mode; Automatic Operation - Renkforce RDM PAR-Spot 6 x 10 W Bedienungsanleitung

Led-spot
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

d) Programming mode
In this mode, you can define 6 individual programmes with up to 30 programme interfaces.
The definition of the individual programme steps takes place in the menu EdIt, selection of the programme
and the programme speed takes place in the menu chAS.
Programme definition
• Select the programme Pr.01-Pr.06 to be defined in the menu EdIt.
• Select Sc.01 to define the first programme step.
• Define the desired colour of the first programme step by setting the colour intensities of the individual
LEDs as follows:
r.000-r.255
G.000-G.255
b.000-b.255
A.000-A.255
u.000-u.255
• Select Sc.02 to define the second programme step.
• Continue as described above to define all programme steps (up to 30) for the respective programme.
• Select Pr.02 to choose the next programme to be defined. Up to 6 such programmes are programmable.
• Continue as described above to define all programme steps for this programme as well.
Call of a pre-defined programme
• Select the desired programme Pr.01-Pr.06 in menu chAS.
• Use the buttons UP or DOWN to set the desired programme speed (t0.01-t30.0).
e) Automatic operation
In this operating mode, the effect light is operated with pre-programmed programmes.
• Select the desired programme At.01 or At.02 in menu chAS.
• Use the buttons UP or DOWN to set the desired programme speed (t0.01-t30.0).
32
Intensity red
Intensity green
Intensity blue
Intensity amber
Intensity white