11. Maintenance

Regularly check the technical safety of the effect spotlight, e.g. for damage to the mains cable or the cas-
ing.
If you have reason to believe that the device can no longer be operated safely, disconnect it immediately
and make sure it is not operated unintentionally. Pull the mains plug from the mains socket!
It can be assumed that safe operation is no longer possible if:
• the device shows visible damage
• the device is no longer working
• the device has been stored under unfavourable conditions for an extended period of time or
• the device has been subjected to heavy stress during transport.
Always observe the following safety instructions before cleaning or servicing the effect spotlight:
Live components may be exposed if covers are opened or components are removed.
The device must be disconnected from all power sources before any servicing or repair work
is carried out.
Capacitors inside the device may still carry voltage even though they have been disconnected
from all power sources.
Only qualified experts familiar with the hazards involved and the relevant regulations must
perform repairs.

a) Cleaning

The outside of the effect light should only be cleaned with a soft, dry cloth or brush.
Never use any aggressive cleaning agents or chemical solutions as these may damage the surface of the
casing.
b) Fuse replacement
If you have to replace the fuse, ensure that you only use fuses of the specified type and rated current (see
"Technical data") as a replacement.
Never repair fuses or bridge the fuse holder.
• Unplug the mains adapter from the mains socket.
• Use a suitable screwdriver to carefully turn out the fuse holder FUSE with the defective fuse.
• Remove the defective fuse and replace it by a new fuse of the indicated type.
• Now carefully screw the fuse holder FUSE with the new fuse back into its mount in the device.
• After this, you can reconnect the device to the mains and take it into operation.