MEMORY FUNCTION:

If the air humidifier is turned on and power has not been disconnected
since last programming of air humidity, the programmed value is saved and
the appliance will humidify the air of the room according to this last pro-
grammed value.
If the power supply has been disrupted, the previously programmed air hu-
midity value is erased. In this case, the appliance will humidify to the manu-
facturer set standard value of 55%. Should you desire a different value the
machine has to be user programmed anew.
Warm mist button – This button allows setting of the warm mist intensity.
The higher the warm vaporisation, the warmer the steam and the higher the
humidification capacity with warm mist will be. You have four different possi-
bilities: High warm nebulisation, intermediate warm nebulisation, low warm
nebulisation or disabled warm nebulisation. In this last case, the appliance
will operate with cold mist only - here too, three different humidification
levels can be set.
Timer button – Pressing this button will activate the timer. Each touch of
the button will increase operation time by one hour. Humidification time can
be set between 1 and 12 hours. The sum of all illuminated hour digits in the
display gives the set operation time.
Please note the following:
The operating range of your air humidifier is between 5 °C and 45 °C, air
humidity in the room should be below 90%.
Water that has been decalcified by a plant operating with salt is not suitable
for your Ultrasonic Hybrid. The decalcifying cartridge of the humidifier can
not absorb the salt, causing white deposits all over the machine. Should
white deposits form anyway, the cartridge capacity has depleted. When this
happens can vary, depending on water hardness. In this case please replace
the decalcifying cartridge.
The decalcifying cartridge has to be soaked in water for 24 hours before use.
We do not recommend using this machine if your water hardness exceeds
25 °fH.
Never add additives like essential oils or perfumes to the water!
CAUTION: When operating the machine after not using it for extended periods of
time, we recommend cleaning of water tank, mist duct and nebulisation chamber
in any case (see „Cleaning" section).