8.5 Continuity testing with buzzer and red LED
-
With the rotating switch  , select the desired function (Ω,
ZA-TEC ZA 6-2.
-
Using the blue key 4 on the ZA-TEC ZA 6-2, switch to continuity testing ( ).
-
Connect the black safety measuring lead to the COM socket  on the
ZA-TEC ZA 6-2.
-
Connect the red safety measuring lead to the socket  on the
ZA-TEC ZA 6-2.
-
Contact the measuring points with the safety measuring leads. If the line
resistance between the COM jack  and the jack  falls below 20 Ω to
200 Ω, the integrated buzzer of the ZA-TEC ZA 6-2 sounds and the red LED
N lights up.
See fig. 8:

8.6 Capacitance measurement

Discharge capacitors fully before measurement! Never apply
voltage to the sockets for capacitance measurement as this
may cause irreparable damage to the unit. A damaged unit may
represent an electrical hazard!
-
With the rotating switch  , select the desired function (
ZA-TEC ZA 6-2.
-
Determine the polarity of the capacitor and discharge it completely.
-
Connect the black safety measuring lead to the COM socket  on the
ZA-TEC ZA 6-2.
-
Connect the red safety measuring lead to the socket  on the
ZA-TEC ZA 6-2.
-
Contact the discharged capacitor with the safety measuring leads observing
correct polarity. Read the measurement value on the digital display  of the
ZA-TEC ZA 6-2.
See fig. 9:
8.7 Frequency measurement
-
Use the rotary switch 9 to select the desired function (
ZA-TEC ZA 6-2.
-
Connect the black safety measuring lead to the COM socket  on the
ZA-TEC ZA 6-2.
-
For frequency measurement in the voltage range, connect the red safety
measuring lead to the jack  of the ZA-TEC ZA 6-2 and press the key (blue)
4 to switch over to frequency mea surement (Hz).
-
For frequency measurement in the current range, connect the red safety
measuring lead to the jack L of the ZA-TEC ZA 6-2 and press the key (blue)
4 to switch over to frequency measurement (Hz).
-
Remember the minimum sensitivity for frequency measurements using the
ZA-TEC ZA 6-2!
-
Contact the measuring points with the safety measuring leads and read the
measurement result on the digital display  on the ZA-TEC ZA 6-2.
See fig. 10:
8.8 Voltage indicator
The voltage indicator function is not intended for testing the
absence of voltage. Even without an indication or acoustic
signal, a dangerous contact voltage might be applied. Electrical
danger!
-
With the rotating switch 9 , select the desired function (VoltSense) on the
ZA-TEC ZA 6-2.
-
Press the blue key 4 to switch over to Hi (high sensitivity) or Lo (low sensi-
tivity).
-
The voltage indicator function does not need any measuring lines (non-
contact detection of an alternating field). The detector is located on the top
side of the ZA-TEC ZA 6-2. In case of a phase voltage being localized, an
acoustic signal is emitted and the red LED N on the top side of the device
lights. An indication is shown in earthed AC mains only!
Practical hint:
Interruptions (cable breaks) in cables lying around openly such as e.g. cable
reels, fairy lights etc. can be traced from the feeding point (phase) to the point
of interruption.
Functional range: ≥ 230 V
See figure 11:
11/ 2016
Continuity testing with buzzer
Capacity measurement
Frequency measurement
Voltage indicator with buzzer
ZA-TEC ZA 6-2
) on the
) on the
Hz or
Hz) of the
25