Herunterladen Inhalt Inhalt Diese Seite drucken

ZA-TEC ZA 6-2 Bedienungsanleitung Seite 22

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Crest factor of 2.0 to 2.5, additional error + 5.0 %.
Crest factor of 2.5 to 3.0, additional error + 7.0 % (applies to up to 4000 digits).
7.1 DC voltage ranges
The input resistance is 10 MΩ
Overload protection: 1000 V
Measuring range
6.000 V
60.00 V
600.0 V
1000 V
7.1.1
DC voltage ranges mV DC
The input resistance is 10 MΩ
Overload protection: 1000 V
Measuring range
600.0 mV
7.2 AC voltage ranges
The input resistance is 10 MΩ parallel < 100 pF.
Overload protection: 1000 V
Measuring
OL indication
range
600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
*
Measuring range from ≥ 1.0 mV
7.3 AutoV, "LoZ" range
The low-impedance input resistance of approx. 3 kΩ serves to suppress induc-
tive and capacitive voltages.
Overload protection: 1000 V
Measuring
OL indication Resolution
range
600.0 V
1000 V
*
Measuring range from ≥ 1.0 mV
7.4 DC current ranges
Overload protection:
-
11 A (1000 V AC/ DC) fuse, 20 kA, rapid on 10 A input
Max. measuring time:
-
3 minutes at > 5 A (pause > 20 minutes)
-
30 secondes at > 10 A (pause > 10 minutes)
Measuring range
6.000 A
10.00 A
7.5 AC current ranges
Overload protection:
-
11 A (1000 V AC/ DC) fuse, 20 kA, rapid on 10 A input
Max. measuring time:
-
3 minutes at > 5 A (pause > 20 minutes)
-
30 secondes at > 10 A (pause > 10 minutes)
Measuring
OL indication
range
6.000 A
10.00 A
*
6 A measuring range from ≥ 20 mA, 10 A measuring range from ≥ 100 mA
11/ 2016
AC/DC
OL indication
6.600 V
66.00 V
660.0 V
1100 V
AC/DC
OL indication
660.0 mV
AC/DC
Resolution
660.0 mV
0.1 mV
6.600 V
0.001 V
66.00 V
0.01 V
660.0 V
0.1 V
1100 V
AC/DC
660.0 V
100 mV
1100 V
1 V
OL indication
6.600 A
20.00 A
Resolution
6.600 A
0.001 A
20.00 A
0.01 A
ZA-TEC ZA 6-2
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 mV
in frequency range 45 Hz - 500 Hz (sine)
± (1.0 % of reading + 8 digits)*
± (1.0 % of reading + 5 digits)
± (1.0 % of reading + 5 digits)
± (1.0 % of reading + 5 digits)
1 V
± (1.0 % of reading + 5 digits)
in frequency range 45 Hz - 500 Hz (sine)
± (2.0 % of reading + 5 digits)*
± (2.0 % of reading + 5 digits)
Resolution
0.001 A
0.01 A
in frequency range 45 Hz - 500 Hz (sine)
± (1.5 % of reading + 5 digits)*
± (1.5 % of reading + 5 digits)*
Measurement accuracy
± (0.5 % of reading + 5 digits)
± (0.5 % of reading + 5 digits)
± (0.5 % of reading + 5 digits)
± (0.5 % of reading + 5 digits)
Measurement accuracy
± (0.5 % of reading + 8 digits)
Measurement accuracy
Measurement accuracy
Measurement accuracy
± (1.0 % of reading + 5 digits)
± (1.0 % of reading + 5 digits)
Measurement accuracy
22

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für ZA-TEC ZA 6-2