20 µF
200 µF
2 mF
< 10 digits in case of fluctuating indication

7.8 Frequency ranges

Overload protection for frequency measurements: 600 V
Minimum pulse width > 25 ns; operating cycle limitation > 30 % and < 70 %
Measuring
Resolution
range
2 kHz
1 Hz
20 kHz
10 Hz
200 kHz
100 Hz
2 MHz
1 kHz
20 MHz
10 kHz
7.9 Temperature ranges °C
Temperature measurements are possible by means of the enclosed temperature
measuring adapter only.
Overload protection for temperature measurements: 600 V
Measuring range
-20 °C ~ 0 °C
1 °C ~ 100 °C
101 °C ~ 500 °C
501 °C ~ 800 °C
7.10 Temperature ranges °F
Temperature measurements are possible by means of the enclosed temperature
measuring adapter only.
Overload protection for temperature measurements: 600 V
Measuring range
-4 °F ~ 32 °F
33 °F ~ 212 °F
213 °F ~ 932 °F
933 °F ~ 1472 °F
8.

Measuring with the ZA-TEC ZA 1-3

8.1 Preparing the measurement

Operate and store the ZA-TEC ZA 1-3 at the specified storage and operating
temperatures only!
Do not permanently expose the device to sunlight.
-
Check stated nominal voltage and nominal current on the safety measuring
leads. Nominal voltage and current of the enclosed safety measuring leads
comply with the respective values of the ZA-TEC ZA 1-3.
-
Check insulation of the safety measuring leads. If the insulation is damaged,
the safety measuring leads must be replaced immediately.
-
Check the safety measuring leads for continuity. If the conductor in the
safety measuring lead is interrupted, replace the safety measuring leads
immediately.
-
Before selecting another function by means of the rotary switch , discon-
nect the safety measuring leads from the measuring point.
-
Strong sources of interference in the vicinity of the ZA-TEC ZA 1-3 might in-
volve unstable readings and measuring errors.
8.2 Voltage and current measurement
Do not exceed the maximum permitted voltage with respect to
earth potential! Electrical danger!
The highest voltage which may be applied to the
-
COM jack J
-
jack for V, Ω,
-
jack for the 10 A range K
11/ 2016
10 nF
100 nF
1 µF
Measuring accuracy for 5 V
± (0.01 % of the measured value + 1 digits)
± (0.01 % of the measured value + 1 digits)
± (0.01 % of the measured value + 1 digits)
± (0.01 % of the measured value + 1 digits)
± (0.01 % of the measured value + 1 digits)
Resolution
Resolution
, Hz 9
ZA-TEC ZA 1-3
± (1.9 % of the measured value + 8 digits)
± (1.9 % of the measured value + 8 digits)
± (1.9 % of the measured value + 8 digits)
max.
eff
1 °C
1 °C
1 °C
1 °C
1 °F
1 °F
1 °F
1 °F
eff
Sensitivity
> 1.5 < 5 V
> 1.5 < 5 V
> 1.5 < 5 V
> 2 < 5 V
> 2 < 5 V
eff
Measuring accuracy
± (2 % + 4 °C)
± (1 % + 3 °C)
± (2 % + 3 °C)
± (3 % + 2 °C)
eff
Measuring accuracy
± (2 % + 8 °F)
± (1 % + 6 °F)
± (2 % + 6 °F)
± (3 % + 4 °F)
eff
eff
eff
eff
eff
16