(IEC 6 LR 61).
-
The above mentioned safety cable (tested spare part) are approved in
accordance with CAT III 1000 V/ CAT IV 600 V and for a current up 10 A.
4.

Description of unit

See fig. 1:
The display and operating elements shown in fig. 1 are as follows:
 Digital display, for the measurement reading and display for overrange
indication,
 Polarity display,
 Battery display,
 Function key (blue),
 RANGE key, switchover between automatic and manual measuring range,
 Δ/PEAK key, relative value function and peak value storage
 Smart HOLD key,
8 Button (yellow), display illumination,
 Rotating switch, for selecting measuring function.
 Socket (positive
 COM socket, joint socket for measurement of current, voltage, resistance,
frequency, temperature, capacity, continuity and diode testing,
 Socket (positive), for 10-A range, for currents up to 10 A
 Protective rubber holster
 LED (red) for voltage indicator and continuity test
) The automatic polarity display for DC current and voltage refers to this.
1
5.

General data

5.1 General data on multimeter
5.1.1
The digital display 1 is designed as a 4 digit liquid-crystal indicator with
15 mm digit height and decimal point. The highest value displayed is 6000.
5.1.2
The bar graph display consists of 60 segments.
5.1.3
The polarity indication  functions automatically. Only a polarity con-
trary to the socket definition is indicated, as "-".
5.1.4
The range overload will be displayed with "OL" or "-OL" and sometimes
with an acoustic signal.
Attention: no display or warning by complete overload.
5.1.5
The rotary switch 9 is intended for selecting the measuring function.
5.1.6
The "RANGE" key 5 can be used to change over to the manual meas-
uring ranges and to hide "AUTO" on the display at the same time. By
pressing the key for approx. 2 seconds, the automatic range selection is
activated ("AUTO" on the display).
5.1.7
Press the Δ/PEAK key 6 (relative value function) to store the currently
displayed value and to display the difference (offset) between the stored
measured value and the following measured values. Press the Δ/PEAK
key 6 for 2 seconds to switch over to the "PEAK" function (peak value
storage). The "PEAK" function detects and stores the positive and
negative peak/ crest value (> 1 ms) in the mV, V AC/ DC and mA, A
AC/ DC function. Press the key to call up Pmax, Pmin and the currently
measured value (Pmax, Pmin). Press the key for approx. 2 seconds to
switch the device back to normal operating mode.
5.1.8
"Smart HOLD" - storage of measurement reading: When the "Smart HOLD"
key  is pressed, the measurement reading is stored in the memory.
The symbol "HOLD" appears in the display 1 at the same time. If the
measured value increases by 50 digit above the saved value the change
in measured value is shown by a blinking display and by a signal tone.
(changes of measured values between AC and DC voltage/ current will
not be recognized).
5.1.9
Press the yellow key 8 to activate the display illumination. The device is
switched off automatically after 2 seconds or by pressing the key again.
5.1.10 The function key (blue) 4 serves to select the secondary function of the
rotary switch position.
Switch position
11/ 2016
Front panel
) for V, Ω,
1
Hz
Hz
ZA-TEC ZA 6-2
, Hz
Function
► Hz
Ω
► Hz
20