Operation

The manual transmitter as part of our scope of delivery is taught in for the 12 V control box. The 12 V control box has
to be adapted to every further manual transmitter.
Teaching-in manual transmitter (J):
The receiver is equipped with a teach-in button (24) to adapt the 12 V control box to the transmission signal of the
manual transmitter.
− Insert a pin (23) into the opening for the teach-in button (24) until you feel a resistance. Keep pressing in the pin (23)
until this resistance is overcome. The teach-in button (24) is then activated.
− Actuate the teach-in button (24) using the pin (23) for approx. 1 sec.
− Then press any button of the manual transmitter for at least 1 sec.
Deleting the manual transmitter (J):
− Actuate the teach-in button (24) using a pin (23) for at least 5 sec.
This deletes all manual transmitters stored in the receiver.
Note: A maximum of 10 manual transmitters can be set to the receiver. The manual transmitter has a maximum range
of 80 m. Obstacles between transmitter and receiver, a low battery in the manual transmitter, or electro-magnetic
radiation of electrical equipment will impair the range.
Aligning the water fountain (K):
− Swivel the LED light nozzle (25) to align the water fountain.

Remedy of faults

Malfunction
Pumps do not start
Unit does not respond to manual transmitter
Insufficient fountain height
Unit switches off after a brief running time
(approx. 10 s)
13666-02-14_Water Quintet Creati15 15
the manual transmitter (A, 7) can be used to select 9 programmed water feature patterns.
Program 1 appears automatically when starting up and with each new start of the unit.
P0
Unit off, stand-by mode
P1
All fountains active, fixed height up to max. 30 cm
Light on for all fountains
P2
All fountains active, fixed height up to max. 70 cm
Light on for all fountains
P3
All fountains active, dynamic fountain height, max. 70 cm high
Light on for all fountains
P4
One fountain each alternatingly active in intervals, max. 70 cm high
Light switched on for each active fountain
P5
All fountains active, fixed height up to max. 110 cm
Light on for all fountains
P6
All fountains active, dynamic fountain height, max. 110 cm high
Light on for all fountains
P7
One fountain each alternatingly active in intervals, max. 140 cm high
Light switched on for each active fountain
P8
All fountains active, dynamic fountain height, max. 140 cm high
Light on for all fountains
P9
Several fountains alternatingly active, max. 140 cm high
Light switched on for the respective active fountains
Select next program: Button 1
Select previous program: Button 2
Note:
− If the unit is switched by means of a timer, always program 1 is started.
− Fountain heights can be varied.
Cause
No mains voltage
Manual transmitter not taught in
Impeller blocked or soiled
Pump strainer casing soiled
Nozzles soiled
Water temperature too high
Pumps run dry
- GB -
Remedy
Check mains voltage
Check supply lines
Teach-in manual transmitter
Clean impeller
Clean strainer casing
Clean nozzles
Note maximum water temperature of + 35°C.
For switching on again, pull the power plug and
reinsert in the socket.
Check water level and, if necessary, top up the
water. For switching on again, pull the power
plug and reinsert in the socket.