Correct electrical installation
− Install the transformer at a minimum safety distance of 2 m from the water.
− Install both the 12 V control box at a minimum safety distance of 2 m from the water.
− Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
− A person is regarded as a qualified electrician, if, due to his/her vocational education, knowledge and experience, he
or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the
recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regu-
lations.
− For your own safety, please consult a qualified electrician.
− The unit may only be connected when the electrical data of the unit and the power supply coincide. The unit data is
to be found on the unit type plate or on the packaging, or in this manual.
− Extension cables and power distributors (e. g. outlet strips) must be suitable for outdoor use.
− Only plug the unit into a correctly fitted socket.
Safe operation
− The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
− Only operate the unit with the supplied transformer.
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do not present a
tripping obstacle.
− Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
− Only execute work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Never look directly into the light source of the unit.

Mechanical installation

Setting up the Water Quintet Creative
Information about both installation variants (A, B, C):
To ensure flexible pump installation, the cables can be separated from the cable bundle by opening the cable protec-
tion jacket (A, 36). The following always applies:
− Minimum distance between pump and pond or basin rim: 1.5 m.
− Position the pumps such that they are fully submerged in the water at all times.
− Ensure that the water supply at the pump filter basket is unobstructed (8).
Variant 1 - Firm installation in the ground (C):
− Place the pumps horizontally on a firm ground in the water.
− For larger water depths, screw-connect the extension tubes (6) between the LED light nozzles (10) and the
pumps (12) to equalise differences in height. If this is not practical, select a different place of installation. A maxi-
mum of two extension tubes per pump can be used.
− To prevent floating up, load the pump base with rocks or bolt the pump onto a plate.
Variant 2 - Suspended installation (D):
− Unscrew the nozzle holder (9).
− To suspend the unit, screw one of the supplied extension tubes or both (6) between the LED light nozzle (10) and
the pump (12).
− Hook the pumps in a suitable suspension plate (11). Either allow the nozzle holder (9) to sit on the suspension plate
or insert it to be flush with the plate top face (D).
13666-02-14_Water Quintet Creati13 13