S4 – External Sensor Type
GB
This allows type of remote sensor input to be defi ned.
Setting 0
DE
Setting 1
DK
Setting 2
Setting 3
ES
FR
S5 – Floor Sensor Limit
This allows the remote thermostat limit sensor to be set,
NL
typical application is fl oor heating. If the temperature sensed
by the limit sensor exceeds the limit setting the output will
be turned off until the temperature has dropped by2°C.
RU
Setting
TR
12
No remote sensor fi tted (factory setting)
Remote room sensor fi tted, internal sensor
disabled
Remote limit sensor fi tted, refer to option S5
Digital window switch, refer to option S6
Any value between 20 – 50°C (factory setting
27°C)