Read this manual attentively before starting up the unit. Do
not throw it away. Keep it in your files for future reference.
Improper installation or attachment of equipment or acces-
sories could result in electric chock, short-circuit, leaks, fire
or other damage to the equipment. Be sure only to use ac-
cessories made by Daikin which are specifically designed
for the use with the equipment and have them installed by a
professional.
If unsure of installation procedures or use, always contact
your Daikin dealer for advice and information.
B
efore installation
Installation and maintenance should be carried out by technical per-
sonnel qualified for this type of machine, in compliance with current
safety regulations.
When receiving the unit please check its state, verifying if any damage
occurred during transport.
Refer to the relevant technical sheets for installation and use of possi-
ble accessories.
Identify model and version of the unit from the indications stated on the
carton package.
U
se and operating limits
Daikin shall not be held liable
- if the unit has been installed by non-qualified personnel,
- if the unit has been used improperly,
- if the unit has been used under conditions that are not permitted,
- if maintenance operations specified in this manual have not been
carried out,
- if non original spare parts have been used.
Keep the unit in its packaging until it is ready to be installed, to prevent
dust getting inside.
Air sucked by the unit must always be filtered. Always use the supplied
air filter.
If the unit is not used during winter, drain the water from the system to
prevent damage caused by the formation of ice. If antifreeze solutions
are used, check the freezing point.
Do not change the internal wiring or other parts of the unit.
Operating limits are shown here below; all other uses are considered
improper:
thermal carrier: water/glycol
n
water temperature: 5°C~95°C
n
maximum operating pressure: 10 bar
n
air temperature: –20°C~43°C
n
voltage tolerance: ±10%
n
Installation and operation manual
1
Ducted fan coil units
Selection of location:
do not install the unit in rooms where inflammable gases are pre-
n
sent
do not let water spray directly on the unit;
n
install the unit on ceilings or walls that bear its weight. Leave
n
enough space all around for proper operation and maintenance of
the unit, taking into account all installed optional accessories.
never place the heating unit immediately under an electric plug-
n
socket.
d
escription of the eqUipment
The FWD range of air conditioning and hot-air heating units has been
implemented for conditioning rooms that require the installation of
ducted units.

Main components

load bearing structure made of galvanized steel sheet of suita-
n
ble thickness, duly insulated with noise-proof/anti-condensing
material, self-extinguishing in class 1. Complete with inspection
panels.
Fan unit with single or dual fan wheel, dual intake centrifugal
n
type, with statically and dynamically balanced impellers, coupled
directly to the 3-speed electric motor, equipped with permanently
fit condenser and thermal safety device
terminal strip.
n
Heat exchanger: high efficiency, made of copper tube and alumi-
n
nium fins secured to the tubes by mechanical expansion. They
are fit with brass manifolds and contain air valves. The heat
exchanger, normally supplied with left-hand attachments, may be
turned 180°.
system for collecting and discharging condensate, setup ei-
n
ther for ceiling or wall mounting. All FWD range models may be
installed either in a horizontal or in a vertical position.
air intake module with air filter
n
n air intake module
Made of galvanised steel sheet. These modules permit to filter
the air sucked up by the unit and also to connect the unit to the
intake channelling.
n air filter
Made of acrylic material, self-extinguishing in class 1, with filte-
ring class EU 2.
The filter may be inserted or removed and is fixed by means of 2
knobs with M4 threaded stems.
The filtering material may be washed and regenerated to main-
tain the rated filtering efficiency with limited charge leaks.
n the accessory kit comprises
-
Load-bearing structure made of galvanised steel sheet
-
Removable cassette-type filter (to be pulled out like a drawer)
-
Self-tapping fixing screws
Example for installation
(See figure 1)
1
FWD unit
2
Intake module with air filter
Installation and
operation manual
FWD