If necessary, peel the adhesive label in
the relevant national language off the
accompanying adhesive label sheet
and paste it over the German text on
the appliance.
The appliance allows 2 operating modes:
1 Industry vacuum cleaner mode (socket
not used)
2 Dedusting mode (socket used)
Connect the suction hose and insert the
suction nozzle or connect to the dust-
generating device depending on the op-
erating mode.
WARNING
Do not vacuum without the filter elements;
otherwise, the suction motor can get dam-
aged and this can be hazardous to health
on account of increased release of fine dust
particles.
The horn blows when the air speed falls be-
low 20 m/s.
Note: The horn reacts to negative pres-
sure.
Set the rotary switch to the correct suc-
tion hose cross-section.
Anti-static system
Static charge is deflected by providing
earthing to the connection nozzles. This
prevents the formation of sparks and cur-
rent shocks with attachments with electrical
conductivity (included in the delivery).
Dry vacuum cleaning
– The appliance is equipped with a paper
filter bag fitted with locking lid.
Order No. Safety filter sack: 9039
(5 pieces)
18
Start up
Horn
Note: You can use this appliance to take up
all types of dust up to dust class H. It is stat-
utorily necessary to use a dust collection
bag (see Filter systems for order number).
Note: The appliance is suited as industrial
vacuum cleaner and as dedusting device
for the mobile operation to take up dry, non-
combustible dusts with AGW values.
– Unused flat-fold filters may only be
stored and transported in the packaging
(carton).
Illustration
– The lamella of the flat-fold filter should
not be touched during installation.
WARNING
The flat-fold filter and the safety filter sack
must never be removed during the dust ex-
traction process.
Installing the safety filter sack
Release and remove the suction head.
Illustration
Insert the safety filter sack.
Illustration
Pull the safety filter sack over the con-
tainer.
Insert and lock the suction head.
Wet vacuum cleaning
DANGER
No dusts hazardous to health should be
sucked in during wet vacuuming.
Inserting the rubber lips
Illustration
Remove the brush strips.
Install the rubber lips.
Note: The structured side of the rubber lips
must point outwards.
Close the suction connection
Illustration
Precisely fit the plug into the suction
connection.
Insert the plug up to the stop.
Tightly close the suction connection
with the plug by turning it to the right.
Note: The accurate fit is ensured by means
of a "bayonet connection".
– 3
EN