Installation instructions/Technical data
Power supply:
Impulse voltage withstand level:
Rated power:
Output:
Maximum load:
Align switching time:
Software class:
Operating temperature:
IP class:
Degree of contamination:
Dimensions (L × W × H):
Colour information:
Mark of conformity:
Installation
230VAC, 50 Hz
2.5 kV
2 W
230VAC, 50 Hz
250VAC, 3A, cos f > 0.8 ind.
120 seconds
A
0 ºC (32 ºF) to +40 ºC (104 ºF)
IP 40
2
69 × 69 × 54 mm
signal white (similar to RAL 9016)
p
- 69 -
Installation
G
G
Wiring diagram
- 70 -