Astro function / Run time correction

Below the switching sequence is presented in the course of an entire year under con-
sideration of summer/winter time, at an up time preset at 6:30 and a down time preset
at 19:30. These times relate to 10° of eastern longitude and 50° of northern latitude
which corresponds to the geographical location of the city of Würzburg. Setting DIP
switch 6 to "ON" will delay the down time of the roller shutter by 30 minutes.
DIP 6
Run time
correction:
OFF
ON

Special functions

Correction
no delay
down command 30 minutes delayed
- 57 -
Special functions
DIP 2
DIP 3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Y12345C
The respective DIP switches are located on the rear panel of the control.
G
G
Astro function – Germany
DIP 4
DIP 5
Area
OFF
OFF
Schleswig-Holstein, Northern Lower-Saxony
OFF
ON
Mecklenburg-Vorpommern
ON
OFF
North-Rhine Westphalia, Southern Lower-Saxony
ON
ON
Brandenburg, Saxony-Anhalt
OFF
OFF
Rhineland-Palatinate, Saarland, Hesse
OFF
ON
Saxony, Thuringia
ON
OFF
Baden-Württemberg
ON
ON
Bavaria
= Manufacturer's default setting:
Schleswig-Holstein,
Northern Lower-Saxony